Institute of Fundamental Technological Research
Polish Academy of Sciences

Staff

Katarzyna Dobruch-Sobczak, PhD, DSc

Department of Ultrasound (ZU)
Division of Biomechanics (PB)
position: Main Specialist
telephone: (+48) 22 826 12 81 ext.: 486
room: 518
e-mail:
ORCID: 0000-0003-1470-4140

Habilitation thesis
2022-05-11 Wieloparametryczna analiza obrazowania ultradźwiękowego w różnicowaniu guzów piersi oraz monitorowaniu leczenia chorych dotkniętych rakiem piersi 
Supervision of doctoral theses
1.  2017-09-28
co-supervisor
Byra Michał Klasyfikacja zmian nowotworowych piersi na podstawie własności statystycznych ech ultradźwiękowych 

Recent publications
1.  Pawłowska A., Żołek N., Leśniak-Plewińska B., Dobruch-Sobczak K., Klimonda Z., Piotrzkowska-Wróblewska H., Litniewski J., Preliminary assessment of the effectiveness of neoadjuvant chemotherapy in breast cancer with the use of ultrasound image quality indexes, Biomedical Signal Processing and Control, ISSN: 1746-8094, DOI: 10.1016/j.bspc.2022.104393, Vol.80, No.104393, pp.1-9, 2023

Abstract:
Objective: Neoadjuvant chemotherapy (NAC) in breast cancer requires non-invasive methods of monitoring its effects after each dose of drug therapy. The aim is to isolate responding and non-responding tumors prior to surgery in order to increase patient safety and select the optimal medical follow-up. Methods: A new method of monitoring NAC therapy has been proposed. The method is based on image quality indexes (IQI) calculated from ultrasound data obtained from breast tumors and surrounding tissue. Four different tissue regions from the preliminary set of 38 tumors and three data pre-processing techniques are considered. Postoperative histopathology results were used as a benchmark in evaluating the effectiveness of the IQI classification. Results: Out of ten parameters considered, the best results were obtained for the Gray Relational Coefficient. Responding and non-responding tumors were predicted after the first dose of NAC with an area under the receiver operating characteristics curve of 0.88 and 0.75, respectively. When considering subsequent doses of NAC, other IQI parameters also proved usefulness in evaluating NAC therapy. Conclusions: The image quality parameters derived from the ultrasound data are well suited for assessing the effects of NAC therapy, in particular on breast tumors.

Keywords:
Quantitative ultrasound; Image quality; Neoadjuvant chemotherapy; Breast cancer; Treatment response

Affiliations:
Pawłowska A. - IPPT PAN
Żołek N. - IPPT PAN
Leśniak-Plewińska B. - other affiliation
Dobruch-Sobczak K. - IPPT PAN
Klimonda Z. - IPPT PAN
Piotrzkowska-Wróblewska H. - IPPT PAN
Litniewski J. - IPPT PAN
2.  Śniadecki M., Jaworek P., Chmielewska Z., Poniewierza P., Stasiak M., Danielkiewicz M., Stencelewski D., Brzeziński M., Boyke Zuzanna A., Wycinka E., Sunil M., Nguyen M., Klasa-Mazurkiewicz D., Koziełek K., Rak P., Wolny Y., Liro M., Guzik Paweł W., Dobruch-Sobczak K., Wydra D., Protocol of Breast Cancer Prevention Model with Addition of Breast Ultrasound to Routine Gynecological Visits as a Chance for an Early Diagnosis and Treatment in 25 to 49-Year-Old Polish Females, Diagnostics, ISSN: 2075-4418, DOI: 10.3390/diagnostics13020227, Vol.13, No.227, pp.1-10, 2023

Abstract:
The low attendance rate for cancer screening tests in Poland is a major healthcare concern that requires specific analysis and the development of implementation recommendations for prevention, and both actions are likely to benefit culturally similar countries. Four female cancers account for approximately 20% of all cancer cases—breast cancer, cervical cancer, endometrial cancer, and ovarian cancer—suggesting that gynecologists have a significant preventative role. Of the four, breast cancer and cervical cancer are among the 10 most common malignant neoplasms globally, regardless
of gender, occur only in women and are known to have effective screening measures. Our research aims to create a screening model that combines cervical cancer and breast cancer to maximize health outcomes for women at risk of both cancers. In the study protocol, we have created a model that maximizes benefits for patients with minimal additional costs to the health care system. To achieve the set goal, instead of regular clinical breast exams as recommended by the gynecological societies, we proposed an ultrasound examination, during which palpation may also be performed (in the
absence of elastography). We present a scheme for such a protocol that takes into consideration all types of prevention in both cancers, and that emphasizes breast ultrasound as the most frequently missing element. Our study includes a discussion of the strengths and weaknesses of our strategy, and the crucial need for infrastructure and education for the successful implementation of the program. We conclude that our model merits consideration and discussion among health-care decision makers, as the screening changes we propose have significant potential benefits for the female population.

Keywords:
screening, cervical cancer, breast cancer, ultrasonography, mammography, value-based healthcare, health policy

Affiliations:
Śniadecki M. - other affiliation
Jaworek P. - other affiliation
Chmielewska Z. - other affiliation
Poniewierza P. - other affiliation
Stasiak M. - other affiliation
Danielkiewicz M. - other affiliation
Stencelewski D. - other affiliation
Brzeziński M. - other affiliation
Boyke Zuzanna A. - other affiliation
Wycinka E. - other affiliation
Sunil M. - other affiliation
Nguyen M. - other affiliation
Klasa-Mazurkiewicz D. - other affiliation
Koziełek K. - other affiliation
Rak P. - other affiliation
Wolny Y. - other affiliation
Liro M. - other affiliation
Guzik Paweł W. - other affiliation
Dobruch-Sobczak K. - IPPT PAN
Wydra D. - other affiliation
3.  Żyłka A., Dobruch-Sobczak K., Jędrzejczyk M., Piotrzkowska-Wróblewska H.E., Gałczyński J., Bakuła-Zalewska E., Dedecjus M., OR32-04 The Usefulness Of The Contrast-enhanced Ultrasound (CEUS) In Evaluating The Risk Of Malignancy In Thyroid Nodules, Journal of the Endocrine Society, ISSN: 2472-1972, Vol.7, No.Suplement 1, pp.1093-1095, 2023

Keywords:
Thyroid, Ultrasound, CEUS

Affiliations:
Żyłka A. - other affiliation
Dobruch-Sobczak K. - IPPT PAN
Jędrzejczyk M. - other affiliation
Piotrzkowska-Wróblewska H.E. - IPPT PAN
Gałczyński J. - other affiliation
Bakuła-Zalewska E. - Institute of Oncology (PL)
Dedecjus M. - Institute of Oncology (PL)
4.  Byra M., Jarosik P., Dobruch-Sobczak K., Klimonda Z., Piotrzkowska-Wróblewska H., Litniewski J., Nowicki A., Joint segmentation and classification of breast masses based on ultrasound radio-frequency data and convolutional neural networks, Ultrasonics, ISSN: 0041-624X, DOI: 10.1016/j.ultras.2021.106682, Vol.121, pp.106682-1-9, 2022

Abstract:
In this paper, we propose a novel deep learning method for joint classification and segmentation of breast masses based on radio-frequency (RF) ultrasound (US) data. In comparison to commonly used classification and segmentation techniques, utilizing B-mode US images, we train the network with RF data (data before envelope detection and dynamic compression), which are considered to include more information on tissue’s physical properties than standard B-mode US images. Our multi-task network, based on the Y-Net architecture, can effectively process large matrices of RF data by mixing 1D and 2D convolutional filters. We use data collected from 273 breast masses to compare the performance of networks trained with RF data and US images. The multi-task model developed based on the RF data achieved good classification performance, with area under the receiver operating characteristic curve (AUC) of 0.90. The network based on the US images achieved AUC of 0.87. In the case of the segmentation, we obtained mean Dice scores of 0.64 and 0.60 for the approaches utilizing US images and RF data, respectively. Moreover, the interpretability of the networks was studied using class activation mapping technique and by filter weights visualizations.

Keywords:
breast mass classification, breast mass segmentation, convolutional neural networks, deep learning, quantitative ultrasound, ultrasound imagin

Affiliations:
Byra M. - IPPT PAN
Jarosik P. - IPPT PAN
Dobruch-Sobczak K. - IPPT PAN
Klimonda Z. - IPPT PAN
Piotrzkowska-Wróblewska H. - IPPT PAN
Litniewski J. - IPPT PAN
Nowicki A. - IPPT PAN
5.  Byra M., Dobruch-Sobczak K., Piotrzkowska-Wróblewska H., Klimonda Z., Litniewski J., Prediction of response to neoadjuvant chemotherapy in breast cancer with recurrent neural networks and raw ultrasound signals, PHYSICS IN MEDICINE AND BIOLOGY, ISSN: 0031-9155, DOI: 10.1088/1361-6560/ac8c82, Vol.67, No.18, pp.1-15, 2022

Abstract:
Objective. Prediction of the response to neoadjuvant chemotherapy (NAC) in breast cancer is important for patient outcomes. In this work, we propose a deep learning based approach to NAC response prediction in ultrasound (US) imaging. Approach. We develop recurrent neural networks that can process serial US imaging data to predict chemotherapy outcomes. We present models that can process either raw radio-frequency (RF) US data or regular US images. The proposed approach is evaluated based on 204 sequences of US data from 51 breast cancers. Each sequence included US data collected before the chemotherapy and after each subsequent dose, up to the 4th course. We investigate three pre-trained convolutional neural networks (CNNs) as back-bone feature extractors for the recurrent network. The CNNs were pre-trained using raw US RF data, US b-mode images and RGB images from the ImageNet dataset. The first two networks were developed using US data collected from malignant and benign breast masses. Main results. For the pre-treatment data, the better performing network, with back-bone CNN pre-trained on US images, achieved area under the receiver operating curve (AUC) of 0.81 (±0.04). Performance of the recurrent networks improved with each course of the chemotherapy. For the 4th course, the better performing model, based on the CNN pre-trained with RGB images, achieved AUC value of 0.93 (±0.03). Statistical analysis based on the DeLong test presented that there were no significant differences in AUC values between the pre-trained networks at each stage of the chemotherapy (p-values > 0.05). Significance. Our study demonstrates the feasibility of using recurrent neural networks for the NAC response prediction in breast cancer US.

Keywords:
breast cancer, deep learning, neoadjuvant chemotherapy, reccurent neural networks, ultrasound imaging

Affiliations:
Byra M. - IPPT PAN
Dobruch-Sobczak K. - IPPT PAN
Piotrzkowska-Wróblewska H. - IPPT PAN
Klimonda Z. - IPPT PAN
Litniewski J. - IPPT PAN
6.  Klimonda z., Karwat P., Dobruch-Sobczak K., Piotrzkowska-Wróblewska H., Litniewski J., Assessment of breast cancer response to neoadjuvant chemotherapy based on ultrasound backscattering envelope statistics, Medical Physics, ISSN: 0094-2405, DOI: 10.1002/mp.15428, Vol.1, pp.1-8, 2022

Abstract:
Purpose: Neo-adjuvant chemotherapy (NAC) is used in breast cancer before tumor surgery to reduce the size of the tumor and the risk of spreading. Monitoring the effects of NAC is important because in a number of cases the response to therapy is poor and requires a change in treatment. A new method that uses quantitative ultrasound to assess tumor response to NAC has been presented. The aim was to detect NAC unresponsive tumors at an early stage of treatment. Methods: The method assumes that ultrasound scattering is different for responsive and nonresponsive tumors. The assessment of the NAC effects was based on the differences between the histograms of the ultrasound echo amplitude recorded from the tumor after each NAC dose and from the tissue phantom, estimated using the Kolmogorov–Smirnov statistics (KSS) and the symmetrical Kullback–Leibler divergence (KLD). After therapy, tumors were resected and histopathologically evaluated. The percentage of residual malignant cells was determined and was the basis for assessing the tumor response. The data set included ultrasound data obtained from 37 tumors. The performance of the methods was assessed by means of the area under the receiver operating characteristic curve (AUC). Results: For responding tumors, a decrease in the mean KLD and KSS values was observed after subsequent doses of NAC. In nonresponding tumors, the KLD was higher and did not change in subsequent NAC courses. Classification based on the KSS or KLD parameters allowed to detect tumors not respond- ing to NAC after the first dose of the drug, with AUC equal 0.83±0.06 and 0.84±0.07, respectively. After the third dose, the AUC increased to 0.90±0.05 and 0.91±0.04, respectively. Conclusions: The results indicate the potential usefulness of the proposed parameters in assessing the effectiveness of the NAC and early detection of nonresponding cases.

Keywords:
breast cancer, neoadjuvant therapy assessment, quantitative ultrasound

Affiliations:
Klimonda z. - IPPT PAN
Karwat P. - IPPT PAN
Dobruch-Sobczak K. - IPPT PAN
Piotrzkowska-Wróblewska H. - IPPT PAN
Litniewski J. - IPPT PAN
7.  Piotrzkowska-Wróblewska H., Dobruch-Sobczak K., Litniewski J., Quantitative ultrasonography as a tool for the evaluation of breast tumor response to neoadjuvant chemotherapy, Journal of Ultrasonography, ISSN: 2084-8404, DOI: 10.15557/JoU.2022.0015, Vol.22, pp.e86-e92, 2022

Abstract:
Neoadjuvant chemotherapy is increasingly becoming the first treatment step in breast cancer. Despite the enormous advantages of this therapy, it is a method characterized by a high level of toxicity and thus carries a huge burden for the patient. Therefore, it is highly desirable to begin monitoring the patient’s response to treatment at an earlier stage. Currently, apart from traditional imaging methods, a completely new technique (in the context of monitoring the outcomes of chemotherapy), called quantitative ultrasound, is gaining popularity. It is a method based on the exact same ultrasound echoes as in traditional ultrasound imaging. The innovative approach of the method is that these echoes are not used for visualization but to characterize the condition of the tissue by parameterizing it with the aid of ultrasound biomarkers. The biomarkers make it possible to assess the state of the tissue at the microscopic level, and thus evaluate changes occurring in the tissue under the influence of treatment at a very early treatment stage. The present paper aims to familiarize the reader with the physical foundations of this method as well as present the latest results of related research.

Keywords:
quantitative ultrasound; breast cancer; neoadjuvant chemotherapy

Affiliations:
Piotrzkowska-Wróblewska H. - IPPT PAN
Dobruch-Sobczak K. - IPPT PAN
Litniewski J. - IPPT PAN
8.  Byra M., Dobruch-Sobczak K., Piotrzkowska-Wróblewska H., Klimonda Z., Litniewski J., Explaining a deep learning based breast ultrasound image classifier with saliency maps, Journal of Ultrasonography, ISSN: 2084-8404, DOI: 10.15557/JoU.2022.0013, Vol.22, pp.e70-e75, 2022

Abstract:
Aim of the study: Deep neural networks have achieved good performance in breast mass classification in ultrasound imaging. However, their usage in clinical practice is still lim¬ited due to the lack of explainability of decisions conducted by the networks. In this study, to address the explainability problem, we generated saliency maps indicating ultrasound image regions important for the network’s classification decisions. Material and methods: Ultrasound images were collected from 272 breast masses, including 123 malignant and 149 benign. Transfer learning was applied to develop a deep network for breast mass clas¬sification. Next, the class activation mapping technique was used to generate saliency maps for each image. Breast mass images were divided into three regions: the breast mass region, the peritumoral region surrounding the breast mass, and the region below the breast mass. The pointing game metric was used to quantitatively assess the overlap between the saliency maps and the three selected US image regions. Results: Deep learning classifier achieved the area under the receiver operating characteristic curve, accuracy, sensitivity, and specific¬ity of 0.887, 0.835, 0.801, and 0.868, respectively. In the case of the correctly classified test US images, analysis of the saliency maps revealed that the decisions of the network could be associated with the three selected regions in 71% of cases. Conclusions: Our study is an important step toward better understanding of deep learning models developed for breast mass diagnosis. We demonstrated that the decisions made by the network can be related to the appearance of certain tissue regions in breast mass US images.

Keywords:
deep learning, breast mass diagnosis, attention maps, explainability

Affiliations:
Byra M. - IPPT PAN
Dobruch-Sobczak K. - IPPT PAN
Piotrzkowska-Wróblewska H. - IPPT PAN
Klimonda Z. - IPPT PAN
Litniewski J. - IPPT PAN
9.  Gumowska M., Szlenk Axana M., Roszkowska-Purska K., Piotrzkowska-Wróblewska H., Secomski W., Dobruch-Sobczak K., Granular Cell Tumor of the Breast Imitating a Malignant Tumor: A Case Report and Review of Literature, Archives of Clinical and Medical Case Reports, ISSN: 2575-9655, DOI: 10.26502/acmcr.96550537, Vol.6, No.5, pp.643-646, 2022

Abstract:
A 22 year-old woman with no family history of breast cancer developed a painful breast tumor in the inner lower quadrant of the left breast. After surgical consultation, ultrasound examination was advised. On ultrasound,the mass demonstrated malignant features such as non-parallel orientation, hypoechogenicity, spiculated margins, posterior shadowing, peripheral vessels on color Doppler and increased stiffness in the tissue surrounding the tumor. Before biopsy, mammography was performed. The mass had higher density than fibroglandular tissue, margins were ill-defined (spiculated) and had no microcalcification. BIRADS 5 category was pre-assigned. Core biopsy revealed granular cell tumor (GCT). The patient is undergoing regular follow-up. Granular cell tumor is rare and generally benign, however, it typically demonstrates malignant features clinically and on obtained diagnostic images. This article highlights the variety of imaging features accompanying benign breast tumors.

Keywords:
Breast Cancer,Breast Ultrasound,Granular Cell Tumor

Affiliations:
Gumowska M. - other affiliation
Szlenk Axana M. - other affiliation
Roszkowska-Purska K. - other affiliation
Piotrzkowska-Wróblewska H. - IPPT PAN
Secomski W. - IPPT PAN
Dobruch-Sobczak K. - IPPT PAN
10.  Dobruch-Sobczak K.S., Piotrzkowska-Wróblewska H., Karwat P., Klimonda Z., Markiewicz-Grodzicka E., Litniewski J., Quantitative assessment of the echogenicity of a breast tumor predicts the response to neoadjuvant chemotherapy, Cancers, ISSN: 2072-6694, DOI: 10.3390/cancers13143546, Vol.13, No.14, pp.3546-1-22, 2021

Abstract:
The aim of the study was to improve monitoring the treatment response in breast cancer patients undergoing neoadjuvant chemotherapy (NAC). The IRB approved this prospective study. Ultrasound examinations were performed prior to treatment and 7 days after four consecutive NAC cycles. Residual malignant cell (RMC) measurement at surgery was the standard of reference. Alteration in B-mode ultrasound (tumor echogenicity and volume) and the Kullback-Leibler divergence (kld), as a quantitative measure of amplitude difference, were used. Correlations of these parameters with RMC were assessed and Receiver Operating Characteristic curve (ROC) analysis was performed. Thirty-nine patients (mean age 57 y.) with 50 tumors were included. There was a significant correlation between RMC and changes in quantitative parameters (KLD) after the second, third and fourth course of NAC, and alteration in echogenicity after the third and fourth course. Multivariate analysis of the echogenicity and KLD after the third NAC course revealed a sensitivity of 91%, specificity of 92%, PPV = 77%, NPV = 97%, accuracy = 91%, and AUC of 0.92 for non-responding tumors (RMC ≥ 70%). In conclusion, monitoring the echogenicity and KLD parameters made it possible to accurately predict the treatment response from the second course of NAC.

Keywords:
quantitative ultrasound, B-mode ultrasound, echogenicity, breast cancer, neoadjuvant chemotherapy

Affiliations:
Dobruch-Sobczak K.S. - IPPT PAN
Piotrzkowska-Wróblewska H. - IPPT PAN
Karwat P. - IPPT PAN
Klimonda Z. - IPPT PAN
Markiewicz-Grodzicka E. - Oncology Institute (PL)
Litniewski J. - IPPT PAN
11.  Dobruch-Sobczak K., Piotrzkowska-Wróblewska H., Klimonda Z., Karwat P., Roszkowska-Purska K., Clauser P., Baltzer P.A.T., Litniewski J., Multiparametric ultrasound examination for response assessment in breast cancer patients undergoing neoadjuvant therapy, Scientific Reports, ISSN: 2045-2322, DOI: 10.1038/s41598-021-82141-3, Vol.11, pp.2501 -1-9, 2021

Abstract:
To investigate the performance of multiparametric ultrasound for the evaluation of treatment response in breast cancer patients undergoing neoadjuvant chemotherapy (NAC). The IRB approved this prospective study. Breast cancer patients who were scheduled to undergo NAC were invited to participate in this study. Changes in tumour echogenicity, stiffness, maximum diameter, vascularity and integrated backscatter coefficient (IBC) were assessed prior to treatment and 7 days after four consecutive NAC cycles. Residual malignant cell (RMC) measurement at surgery was considered as standard of reference. RMC < 30% was considered a good response and > 70% a poor response. The correlation coefficients of these parameters were compared with RMC from post-operative histology. Linear Discriminant Analysis (LDA), cross-validation and Receiver Operating Characteristic curve (ROC) analysis were performed. Thirty patients (mean age 56.4 year) with 42 lesions were included. There was a significant correlation between RMC and echogenicity and tumour diameter after the 3rd course of NAC and average stiffness after the 2nd course. The correlation coefficient for IBC and echogenicity calculated after the first four doses of NAC were 0.27, 0.35, 0.41 and 0.30, respectively. Multivariate analysis of the echogenicity and stiffness after the third NAC revealed a sensitivity of 82%, specificity of 90%, PPV = 75%, NPV = 93%, accuracy = 88% and AUC of 0.88 for non-responding tumours (RMC > 70%). High tumour stiffness and persistent hypoechogenicity after the third NAC course allowed to accurately predict a group of non-responding tumours. A correlation between echogenicity and IBC was demonstrated as well.

Affiliations:
Dobruch-Sobczak K. - IPPT PAN
Piotrzkowska-Wróblewska H. - IPPT PAN
Klimonda Z. - IPPT PAN
Karwat P. - IPPT PAN
Roszkowska-Purska K. - other affiliation
Clauser P. - other affiliation
Baltzer P.A.T. - other affiliation
Litniewski J. - IPPT PAN
12.  Byra M., Dobruch-Sobczak K., Klimonda Z., Piotrzkowska-Wróblewska H., Litniewski J., Early prediction of response to neoadjuvant chemotherapy in breast cancer sonography using Siamese convolutional neural networks, IEEE Journal of Biomedical and Health Informatics, ISSN: 2168-2208, DOI: 10.1109/JBHI.2020.3008040, Vol.25, No.3, pp.797-805, 2021

Abstract:
Early prediction of response to neoadjuvant chemotherapy (NAC) in breast cancer is crucial for guiding therapy decisions. In this work, we propose a deep learning based approach for the early NAC response prediction in ultrasound (US) imaging. We used transfer learning with deep convolutional neural networks (CNNs) to develop the response prediction models. The usefulness of two transfer learning techniques was examined. First, a CNN pre-trained on the ImageNet dataset was utilized. Second, we applied double transfer learning, the CNN pre-trained on the ImageNet dataset was additionally fine-tuned with breast mass US images to differentiate malignant and benign lesions. Two prediction tasks were investigated. First, a L1 regularized logistic regression prediction model was developed based on generic neural features extracted from US images collected before the chemotherapy (a priori prediction). Second, Siamese CNNs were used to quantify differences between US images collected before the treatment and after the first and second course of NAC. The proposed methods were evaluated using US data collected from 39 tumors. The better performing deep learning models achieved areas under the receiver operating characteristic curve of 0.797 and 0.847 in the case of the a priori prediction and the Siamese model, respectively. The proposed approach was compared with a
method based on handcrafted morphological features. Our study presents the feasibility of using transfer learning with CNNs for the NAC response prediction in US imaging.

Keywords:
breast cancer, deep learning, neoadjuvant chemotherapy, Siamese convolutional neural networks, ultrasound imaging

Affiliations:
Byra M. - IPPT PAN
Dobruch-Sobczak K. - IPPT PAN
Klimonda Z. - IPPT PAN
Piotrzkowska-Wróblewska H. - IPPT PAN
Litniewski J. - IPPT PAN
13.  Korczak I., Romowicz A., Gambin B., Palko T., Kruglenko E., Dobruch-Sobczak K., Numerical prediction of breast skin temperature based on thermographic and ultrasonographic data in healthy and cancerous breasts, Biocybernetics and Biomedical Engineering, ISSN: 0208-5216, DOI: 10.1016/j.bbe.2020.10.007, Vol.40, pp.1680-1692, 2020

Abstract:
Breast cancer is one of the most common women's cancers, so an available diagnostic modality, particularly non-invasive, is important. Infrared thermography (IRT) is a supporting diagnostic modality. Until now, many finite element methods (FEM) numerical models have been constructed to evaluate IRT's diagnostic value and to relate breast skin temperature characteristics with breast structural disorder presence, particularly to distinguish between cancerous types and normal structures. However, most of the models were not based on any clinical data, except for several papers based on clinical magnetic resonance imaging (MRI) data, wherein a three-dimensional (3D) breast model was studied. In our paper, we propose a very simplified numerical two-dimensional FEM model constructed based on clinical ultrasound data of breasts, which is much cheaper and available in realtime as opposed to MRI data. We show that our numerical simulations enabled us to distinguish between types of healthy breasts in agreement with the clinical classification and with thermographic results. The numerical breast models predicted the possibility of differentiation of cancerous breasts from healthy breasts by significantly different skin temperature variation ranges. The thermal variations of cancerous breasts were in the range of 0.5 8C–3.0 8C depending on the distance of the tumor from the skin surface, its size, and the cancer type. The proposed model, due to its simplicity and the fact that it was constructed based on clinical ultrasonographic data, can compete with the more sophisticated 3D models based on MRI.

Keywords:
non-invasive cancer detection, Pennes' bioheat transfer equation, finite element method, breast thermography, ultrasonography

Affiliations:
Korczak I. - IPPT PAN
Romowicz A. - other affiliation
Gambin B. - IPPT PAN
Palko T. - other affiliation
Kruglenko E. - IPPT PAN
Dobruch-Sobczak K. - IPPT PAN
14.  Klimonda Z., Karwat P., Dobruch-Sobczak K., Piotrzkowska-Wróblewska H., Litniewski J., Breast-lesions characterization using quantitative ultrasound features of peritumoral tissue, Scientific Reports, ISSN: 2045-2322, DOI: 10.1038/s41598-019-44376-z, Vol.9, pp.7963-1-9, 2019

Abstract:
The presented studies evaluate for the first time the efficiency of tumour classification based on the quantitative analysis of ultrasound data originating from the tissue surrounding the tumour. 116 patients took part in the study after qualifying for biopsy due to suspicious breast changes. The RF signals collected from the tumour and tumour-surroundings were processed to determine quantitative measures consisting of Nakagami distribution shape parameter, entropy, and texture parameters. The utility of parameters for the classification of benign and malignant lesions was assessed in relation to the results of histopathology. The best multi-parametric classifier reached an AUC of 0.92 and of 0.83 for outer and intra-tumour data, respectively. A classifier composed of two types of parameters, parameters based on signals scattered in the tumour and in the surrounding tissue, allowed the classification of breast changes with sensitivity of 93%, specificity of 88%, and AUC of 0.94. Among the 4095 multi-parameter classifiers tested, only in eight cases the result of classification based on data from the surrounding tumour tissue was worse than when using tumour data. The presented results indicate the high usefulness of QUS analysis of echoes from the tissue surrounding the tumour in the classification of breast lesions.

Affiliations:
Klimonda Z. - IPPT PAN
Karwat P. - IPPT PAN
Dobruch-Sobczak K. - IPPT PAN
Piotrzkowska-Wróblewska H. - IPPT PAN
Litniewski J. - IPPT PAN
15.  Piotrzkowska-Wróblewska H., Dobruch-Sobczak K., Klimonda Z., Karwat P., Roszkowska-Purska K., Gumowska M., Litniewski J., Monitoring breast cancer response to neoadjuvant chemotherapy with ultrasound signal statistics and integrated backscatter, PLOS ONE, ISSN: 1932-6203, DOI: 10.1371/journal.pone.0213749, Vol.14, No.3, pp.e0213749-1-15, 2019

Abstract:
Background: Neoadjuvant chemotherapy (NAC) is used in patients with breast cancer to reduce tumor focus, metastatic risk, and patient mortality. Monitoring NAC effects is necessary to capture resistant patients and stop or change treatment. The existing methods for evaluating NAC results have some limitations. The aim of this study was to assess the tumor response at an early stage, after the first doses of the NAC, based on the variability of the backscattered ultrasound energy, and backscatter statistics. The backscatter statistics has not previously been used to monitor NAC effects. Methods: The B-mode ultrasound images and raw radio frequency data from breast tumors were obtained using an ultrasound scanner before chemotherapy and 1 week after each NAC cycle. The study included twenty-four malignant breast cancers diagnosed in sixteen patients and qualified for neoadjuvant treatment before surgery. The shape parameter of the homodyned K distribution and integrated backscatter, along with the tumor size in the longest dimension, were determined based on ultrasound data and used as markers for NAC response. Cancer tumors were assigned to responding and non-responding groups, according to histopathological evaluation, which was a reference in assessing the utility of markers. Statistical analysis was performed to rate the ability of markers to predict the final NAC response based on data obtained after subsequent therapeutic doses. Results: Statistically significant differences (p<0.05) between groups were obtained after 2, 3, 4, and 5 doses of NAC for quantitative ultrasound markers and after 5 doses for the assessment based on maximum tumor dimension. Statistical analysis showed that, after the second and third NAC courses the classification based on integrated backscatter marker was characterized by an AUC of 0.69 and 0.82, respectively. The introduction of the second quantitative marker describing the statistical properties of scattering increased the corresponding AUC values to 0.82 and 0.91. Conclusions: Quantitative ultrasound information can characterize the tumor's pathological response better and at an earlier stage of therapy than the assessment of the reduction of its dimensions. The introduction of statistical parameters of ultrasonic backscatter to monitor the effects of chemotherapy can increase the effectiveness of monitoring and contribute to a better personalization of NAC therapy.

Affiliations:
Piotrzkowska-Wróblewska H. - IPPT PAN
Dobruch-Sobczak K. - IPPT PAN
Klimonda Z. - IPPT PAN
Karwat P. - IPPT PAN
Roszkowska-Purska K. - other affiliation
Gumowska M. - other affiliation
Litniewski J. - IPPT PAN
16.  Dobruch-Sobczak K., Piotrzkowska-Wróblewska H., Klimonda Z., Roszkowska-Purska K., Litniewski J., Ultrasound echogenicity reveals the response of breast cancer to chemotherapy, Clinical Imaging, ISSN: 0899-7071, DOI: 10.1016/j.clinimag.2019.01.021, Vol.55, pp.41-46, 2019

Abstract:
Purpose: To evaluate the ultrasound (US) response in patients with breast cancer (BC) during neoadjuvant chemotherapy (NAC). Methods: Prospective US analysis was performed on 19 malignant tumors prior to NAC treatment and 7 days after each first four courses of NAC in 13 patients (median age=57years). Echogenicity, size, vascularity, and sonoelastography were measured and compared with posttreatment scores of residual cancers burden. Results: Changes in the echogenicity of tumors after 3 courses of NAC had the most statistically strong correlation with the percentage of residual malignant cells used in histopathology to assess the response to treatment (odds ratio=60, p < 0.05). Changes in lesion size and elasticity were also significant (p < 0.05). Conclusions: There is a statistically significant relationship between breast tumors' echogenicity in US, neoplasm size, and stiffness and the response to NAC. In particular, our results show that the change in tumor echogenicity could predict a pathological response with satisfactory accuracy and may be considered in NAC monitoring.

Keywords:
breast ultrasonography, neoadjuvant chemotherapy, clinical response, breast cancer, sonoelastography

Affiliations:
Dobruch-Sobczak K. - IPPT PAN
Piotrzkowska-Wróblewska H. - IPPT PAN
Klimonda Z. - IPPT PAN
Roszkowska-Purska K. - other affiliation
Litniewski J. - IPPT PAN
17.  Dobruch-Sobczak K., Piotrzkowska-Wróblewska H., Klimonda Z., Secomski W., Karwat P., Markiewicz-Grodzicka E., Kolasińska-Ćwikła A., Roszkowska-Purska K., Litniewski J., Monitoring the response to neoadjuvant chemotherapy in patients with breast cancer using ultrasound scattering coefficient: a preliminary report, Journal of Ultrasonography, ISSN: 2084-8404, DOI: 10.15557/JoU.2019.0013, Vol.19, No.77, pp.89-97, 2019

Abstract:
Objective: Neoadjuvant chemotherapy was initially used in locally advanced breast cancer, and currently it is recommended for patients with Stage 3 and with early-stage disease with human epidermal growth factor receptors positive or triple-negative breast cancer. Ultrasound imaging in combination with a quantitative ultrasound method is a novel diagnostic approach. Aim of study: The aim of this study was to analyze the variability of the integrated backscatter coefficient, and to evaluate their use to predict the effectiveness of treatment and compare to ultrasound examination results. Material and method: Ten patients (mean age 52.9) with 13 breast tumors (mean dimension 41 mm) were selected for neoadjuvant chemotherapy. Ultrasound was performed before the treatment and one week after each course of neoadjuvant chemotherapy. The dimensions were assessed adopting the RECIST criteria. Tissue responses were classified as pathological response into the following categories: not responded to the treatment (G1, cell reduction by ≤9%) and responded to the treatment partially: G2, G3, G4, cell reduction by 10–29% (G2), 30–90% (G3), >90% (G4), respectively, and completely. Results: In B-mode examination partial response was observed in 9/13 cases (completely, G1, G3, G4), and stable disease was demonstrated in 3/13 cases (completely, G1, G4). Complete response was found in 1/13 cases. As for backscatter coefficient, 10/13 tumors (completely, and G2, G3, and G4) were characterized by an increased mean value of 153%. Three tumors 3/13 (G1) displayed a decreased mean value of 31%. Conclusion: The variability of backscatter coefficient, could be associated with alterations in the structure of the tumor tissue during neoadjuvant chemotherapy. There were unequivocal differences between responded and non-responded patients. The backscatter coefficient analysis correlated better with the results of histopathological verification than with the B-mode RECIST criteria.

Keywords:
integrated backscatter coefficient (IBSCs), neoadjuvant chemotherapy (NAC), breast cancer, ultrasound

Affiliations:
Dobruch-Sobczak K. - IPPT PAN
Piotrzkowska-Wróblewska H. - IPPT PAN
Klimonda Z. - IPPT PAN
Secomski W. - IPPT PAN
Karwat P. - IPPT PAN
Markiewicz-Grodzicka E. - Oncology Institute (PL)
Kolasińska-Ćwikła A. - Institute of Oncology (PL)
Roszkowska-Purska K. - other affiliation
Litniewski J. - IPPT PAN
18.  Piotrzkowska-Wróblewska H., Dobruch-Sobczak K., Byra M., Nowicki A., Open access database of raw ultrasonic signals acquired from malignant and benign breast lesions, Medical Physics, ISSN: 0094-2405, DOI: 10.1002/mp.12538, Vol.44, No.11, pp.6105-6109, 2017

Abstract:
Purpose: The aim of this paper is to provide access to a database consisting of the raw radio-frequency ultrasonic echoes acquired from malignant and benign breast lesions. The database is freely available for study and signal analysis. Acquisition and validation methods: The ultrasonic radio-frequency echoes were recorded from breast focal lesions of patients of the Institute of Oncology in Warsaw. The data were collected between 11/2013 and 10/2015. Patients were examined by a radiologist with 18 yr' experience in the ultrasonic examination of breast lesions. The set of data includes scans from 52 malignant and 48 benign breast lesions recorded in a group of 78 women. For each lesion, two individual orthogonal scans from the pathological region were acquired with the Ultrasonix SonixTouch Research ultrasound scanner using the L14-5/38 linear array transducer. All malignant lesions were histologically assessed by core needle biopsy. In the case of benign lesions, part of them was histologically assessed and another part was observed over a 2-year period. Data format and usage notes: The radio-frequency echoes were stored in Matlab file format. For each scan, the region of interest was provided to correctly indicate the lesion area. Moreover, for each lesion, the BI-RADS category and the lesion class were included. Two code examples of data manipulation are presented. The data can be downloaded via the Zenodo repository (https://doi.org/10.5281/zenodo.545928) or the website http ://bluebox.ippt.gov.pl/~hpiotrzk. Potential applications: The database can be used to test quantitative ultrasound techniques and ultrasound image processing algorithms, or to develop computer-aided diagno sis systems.

Keywords:
breast lesions, dataset, ultrasonic signals, ultrasonography

Affiliations:
Piotrzkowska-Wróblewska H. - IPPT PAN
Dobruch-Sobczak K. - IPPT PAN
Byra M. - IPPT PAN
Nowicki A. - IPPT PAN
19.  Dobruch-Sobczak K., Piotrzkowska-Wróblewska H., Roszkowska-Purska K., Nowicki A., Jakubowski W., Usefulness of combined BI-RADS analysis and Nakagami statistics of ultrasound echoes in the diagnosis of breast lesions, Clinical Radiology, ISSN: 0009-9260, DOI: 10.1016/j.crad.2016.11.009, Vol.72, No.4, pp.339.e7-339.e15, 2017

Abstract:
AIM: To develop a method combining the statistics of the ultrasound backscatter and the Breast Imaging-Reporting and Data System (BI-RADS) classification to enhance the differentiation of breast tumours. MATERIALS AND METHODS: The Nakagami shape parameter m was used to characterise the scatter properties of breast tumours. Raw data from the radiofrequency (RF) echo-signal and Bmode images from 107 (32 malignant and 75 benign) lesions and their surrounding tissue were recorded. Three different characteristic values of the shape parameters of m (maximum [mLmax], minimum [mLmin] and average [mLavg]) and differences between m parameters (Dmmax, Dmmin, Dmavg) of the lesions and their surrounding tissues were assessed. A lesion with a BI-RADS score of 3 was considered benign, while a lesion with a score of 4 was considered malignant (a cut-off of BI-RADS 3/4 was set for all patients). RESULTS: The area under the receiver operating characteristic (ROC) curve (AUC) was equal to 0.966 for BI-RADS, with 100% sensitivity and 54.67% specificity. All malignant lesions were diagnosed correctly, whereas 34 benign lesions were biopsied unnecessarily. In assessing the Nakagami statistics, the sum of the sensitivity and specificity was the best for mLavg (62.5% and 93.33%, respectively). Only four of 20 lesions were found over the cut-off value in BI-RADS of 4a. When comparing the differences in m parameters, Dmavg had the highest sensitivity of 90% (only three of 32 lesions were false negative). These three lesions were classified as BIRADS category 4c. The combined use of B-mode and mLmin parameter improve the AUC up to 0.978 (pĽ0.088), compared to BI-RADS alone.
CONCLUSION: The combination of the parametric imaging and the BI-RADS assessment does not significantly improve the differentiation of breast lesions, but it has the potential to better identify the group of patients with mainly benign lesions that have a low level of suspicion for malignancy with a BI-RADS score of 4a.

Affiliations:
Dobruch-Sobczak K. - IPPT PAN
Piotrzkowska-Wróblewska H. - IPPT PAN
Roszkowska-Purska K. - other affiliation
Nowicki A. - IPPT PAN
Jakubowski W. - other affiliation
20.  Nowicki A., Dobruch-Sobczak K., Introduction to tissue shear wave elastography, HYDROACOUSTICS, ISSN: 1642-1817, Vol.20, pp.129-138, 2017

Abstract:
Ultrasonic elastography is a technique allowing imaging of the elastic properties of tissue. There are two basic techniques of elastographic imaging; compressional - displaying the evaluation of tissue deformation under the external stress; and dynamic, tracking the propagation velocity of the shear wave generated by the acoustic radiation force. Soft tissue bulk modulus varies, from a few to several GPa, whereas the shear modulus is significantly smaller, not exceeding a few hundred Pa for adipose tissue, breast or liver, up to several hundred kPa for hard tissue. Forces generated in the tissue due to the external, axial piston-like stresses depend mainly on the shear modulus. In Shear Wave Elastography, long, several tens of microseconds, ultrasonic pulses successively focused at several depths are sent: generating a conical wave front moving with the supersonic velocity, depending on the tissue stiffness. Velocity of propagation of shear wave depends on the shear modulus μ and the modulus of elasticity E of the examined tissue is equal to E=3μ.

Keywords:
elastography, ultrasonic imaging, thyroid, breast

Affiliations:
Nowicki A. - IPPT PAN
Dobruch-Sobczak K. - IPPT PAN
21.  Dobruch-Sobczak K., Bakuła-Zalewska E., Gumińska A., Słapa R. Z., Mlosek K., Wareluk P., Jakubowski W., Dedecjus M., Diagnostic performance of shear wave elastography parameters alone and in combination with conventional b-mode ultrasound parameters for the characterization of thyroid nodules: a prospective, dual-center study, ULTRASOUND IN MEDICINE AND BIOLOGY, ISSN: 0301-5629, DOI: 10.1016/j.ultrasmedbio.2016.07.010, Vol.42, No.12, pp.2803-2811, 2016

Abstract:
The aims of our study were to determine whether shear wave elastography (SWE) can improve the conventional B-mode differentiation of thyroid lesions, determine the most accurate SWE parameter for differentiation and assess the influence of microcalcifications and chronic autoimmune thyroiditis on SWE values. We examined 119 patients with 169 thyroid nodules who prospectively underwent B-mode ultrasound and SWE using the same ultrasound machine. The parameters assessed using SWE were: mean elasticity within the entire lesion (SWE-whole) and mean (SWE-mean) and maximum (SWE-max) elasticity for a 2-mm-diameter region of interest in the stiffest portion of the lesion, excluding microcalcifications. The discriminant powers of a generalized estimating equation model including B-mode parameters only and a generalized estimation equation model including both B-mode and SWE parameters were assessed and compared using the area under the receiver operating characteristic curve, in association with pathologic verification. In total, 50 and 119 malignant and benign lesions were detected. In generalized estimated equation regression, the B-mode parameters associated with higher odds ratios (ORs) for malignant lesions were microcalcifications (OR = 4.3), hypo-echogenicity (OR = 3.13) and irregular margins (OR = 10.82). SWE-max was the only SWE independent parameter in differentiating between malignant and benign tumors (OR = 2.95). The area under the curve for the B-mode model was 0.85, whereas that for the model combining B-mode and SWE parameters was 0.87. There was no significant difference in mean SWE values between patients with and without chronic autoimmune thyroiditis. The results of the present study suggest that SWE is a valuable tool for the characterization of thyroid nodules, with SWE-max being a significant parameter in differentiating benign and malignant lesions, independent of conventional B-mode parameters. The combination of SWE parameters and conventional B-mode parameters does not significantly improve the diagnosis of malignant thyroid nodules. The presence of microcalcifications can influence the SWE-whole value, whereas the presence of chronic autoimmune thyroiditis may not.

Keywords:
Shear wave elastography, B-Mode ultrasound, Thyroid nodules, Diagnostic performance, Malignant, Benign

Affiliations:
Dobruch-Sobczak K. - other affiliation
Bakuła-Zalewska E. - Institute of Oncology (PL)
Gumińska A. - other affiliation
Słapa R. Z. - other affiliation
Mlosek K. - Medical University of Warsaw (PL)
Wareluk P. - Medical University of Warsaw (PL)
Jakubowski W. - other affiliation
Dedecjus M. - Institute of Oncology (PL)
22.  Byra M., Nowicki A., Piotrzkowska-Wróblewska H., Dobruch-Sobczak K., Classification of breast lesions using segmented quantitative ultrasound maps of homodyned K distribution parameters, Medical Physics, ISSN: 0094-2405, DOI: 10.1118/1.4962928, Vol.43, No.10, pp.5561-5569, 2016

Abstract:
Purpose:
Statistical modeling of an ultrasound backscattered echo envelope is used for tissue characterization. However, in the presence of complex structures within the analyzed area, estimation of parameters is disturbed and unreliable, e.g., in the case of breast tumor classification. In order to improve the differentiation of breast lesions, the authors proposed a method based on the segmentation of homodyned K distribution parameter maps. Regions within lesions of different scattering properties were extracted and analyzed. In order to improve the classification, the best-performing features were selected from various regions and then combined.

Methods:
A radio-frequency data set consisting of 103 breast lesions was used in the authors’ analysis. Maps of homodyned K distribution parameters were created using an algorithm based on signal-to-noise ratio, kurtosis, and skewness of fractional-order envelope moments. A Markov random field model was used to segment parametric maps. Features of different segments were extracted and evaluated based on bootstrapping and the receiver operating characteristic curve. To determine the best-performing feature subset, the authors applied the joint mutual information criterion.

Results:
It was found that there were individual features which performed better than the ones commonly used for lesion characterization, like the parameter obtained through averaging of values over the whole lesion. The authors selected and discussed the best-performing features. Properties of different extracted regions were important and improved the distinction between benign and malignant tumors. The best performance was obtained by combining four features with the area under the receiver operating curve of 0.84.

Conclusions:
The study showed that the analysis of internal changes in lesion parametric maps leads to a better classification of breast tumors. The authors recommend combining multiple features for characterization, instead of using only one parameter, especially in the case of heterogeneous lesions.

Keywords:
Cancer, Ultrasonography, Backscattering, Data sets, Medical image noise

Affiliations:
Byra M. - IPPT PAN
Nowicki A. - IPPT PAN
Piotrzkowska-Wróblewska H. - IPPT PAN
Dobruch-Sobczak K. - IPPT PAN
23.  Nowicki A., Dobruch-Sobczak K., Introduction to ultrasound elastography, Journal of Ultrasonography, ISSN: 2084-8404, DOI: 10.15557/JoU.2016.0013, Vol.16, pp.113-124, 2016

Abstract:
For centuries tissue palpation has been an important diagnostic tool. During palpation, tumors are felt as tissues harder than the surrounding tissues. The significance of palpation is related to the relationship between mechanical properties of different tissue lesions. The assessment of tissue stiffness through palpation is based on the fact that mechanical properties of tissues are changing as a result of various diseases. A higher tissue stiffness translates into a higher elasticity modulus. In the 90’s, ultrasonography was extended by the option of examining the stiffness of tissue by estimating the difference in backscattering of ultrasound in compressed and non-compressed tissue. This modality is referred to as the static, compression elastography and is based on tracking the deformation of tissue subjected to the slowly varying compression through the recording of the backscattered echoes. The displacement is estimated using the methods of cross-correlation between consecutive ultrasonic lines of examined tissue, so calculating the degree of similarity of ultrasonic echoes acquired from tissue before and after the compression was applied. The next step in the development of ultrasound palpation was to apply the local remote tissue compression by using the acoustic radiation force generated through the special beam forming of the ultrasonic beam probing the tissue. The acoustic radiation force causes a slight deformation the tissue thereby forming a shear wave propagating in the tissue at different speeds dependent on the stiffness of the tissue. Shear wave elastography, carries great hopes in the field of quantitative imaging of tissue lesions. This article describes the physical basis of both elastographic methods: compression elastography and shear wave elastography.

Keywords:
elastography, static sonoelastography, dynamic sonoelastography, ultrasonography

Affiliations:
Nowicki A. - IPPT PAN
Dobruch-Sobczak K. - IPPT PAN
24.  Piotrzkowska-Wróblewska H., Dobruch-Sobczak K., Litniewski J., Chrapowicki E., Roszkowska-Purska K., Nowicki A., Differentiation of the breast lesions using statistics of backscattered echoes, HYDROACOUSTICS, ISSN: 1642-1817, Vol.19, pp.319-328, 2016

Abstract:
The purpose of this study was to evaluate the accuracy of statistical properties of the backscttered ultrasound in differential diagnosis of the breast lesions. The B-mode images together with the appropriate RF echoes from the breast lesions and surrounding tissues were collected. The RF data were processed for the statistics of the backscattered echo signals using K and Nakagami distributions characterized by the M and m parameters, respectively. Based on both, M and m parameters, a set of 18 parameters was derived.

From the point of view of the sensitivity of detection of the cancer the best score was obtained using maximum value of M parameter, the best specificity was received using the differential Nakagami parameter (the differential values between lesions and surrounding tissues). In conclusion the quantitative sonography is a method which has potential to be a complementary tool for classification of the breast lesions.

Keywords:
quantitative ultrasound, breast cancer, Nakagami distribution, K dstribution

Affiliations:
Piotrzkowska-Wróblewska H. - IPPT PAN
Dobruch-Sobczak K. - IPPT PAN
Litniewski J. - IPPT PAN
Chrapowicki E. - Center of Oncology Memorial Institute (PL)
Roszkowska-Purska K. - other affiliation
Nowicki A. - IPPT PAN
25.  Dobruch-Sobczak K., Nowicki A., Role of shear wave sonoelastography in differentiation between focal breast lesions, ULTRASOUND IN MEDICINE AND BIOLOGY, ISSN: 0301-5629, DOI: 10.1016/j.ultrasmedbio.2014.08.024, Vol.41, No.2, pp.366-374, 2015

Abstract:
Our goal in this study was to evaluate the relevance of shear wave sonoelastography (SWE) in the differential diagnosis of masses in the breast with respect to ultrasound (US). US and SWE were performed (Aixplorer System, SuperSonic Imagine, Aix en Provence, France) in 76 women (aged 24 to 85) with 84 lesions (43 malignant, 41 benign). The study included BI-RADS-US (Breast Imaging Reporting and Data System for Ultrsound) category 3–5 lesions. In elastograms, the following values were calculated: mean elasticity in lesions (Eav.l) and in fat tissue (Eav.f.) and maximal (Emax.adj.) and mean (Eav.adj.) elasticity in lesions and adjacent tissues. The sensitivity and specificity of the BI-RADS category 4a/4b cutoff value were 97.7% and 90.2%. For an Eav.adj. of 68.5 kPa, the cutoff sensitivity was 86.1% and the specificity was 87.8%, and for an Emax.adj. of 124.1 kPa, 74.4% and 92.7%, respectively. For BI-RADS-US category 3 lesions, Eav.l, Emax.adj. and Eav.adj. were below cutoff levels. On the basis of our findings, Eav.adj. had lower sensitivity and specificity compared with US. Emax.adj. improved the specificity of breast US with loss of sensitivity.

Keywords:
Breast ultrasound, Shear wave sonoelastography, Young's modulus, Focal breast lesions

Affiliations:
Dobruch-Sobczak K. - IPPT PAN
Nowicki A. - IPPT PAN
26.  Dobruch-Sobczak K., Gumińska A., Bakuła-Zalewska E., Mlosek K., Słapa R.Z., Wareluk P., Krauze A., Ziemiecka A., Migda B., Jakubowski W., Dedecjus M., Shear wave elastography in medullary thyroid carcinoma diagnostics, Journal of Ultrasonography, ISSN: 2084-8404, DOI: 10.15557/JoU.2015.0033, Vol.15, pp.358-367, 2015

Abstract:
Shear wave elastography (SWE) is a modern method for the assessment of tissue stiffness. There has been a growing interest in the use of this technique for characterizing thyroid focal lesions, including preoperative diagnostics. Aim: The aim of the study was to assess the clinical usefulness of SWE in medullary thyroid carcinoma (MTC) diagnostics. Materials and methods: A total of 169 focal lesions were identified in the study group (139 patients), including 6 MTCs in 4 patients (mean age: 45 years). B-mode ultrasound and SWE were performed using Aixplorer (SuperSonic, Aix-en-Provence), with a 4–15 MHz linear probe. The ultrasound was performed to assess the echogenicity and echostructure of the lesions, their margin, the halo sign, the height/width ratio (H/W ratio), the presence of calcifications and the vascularization pattern. This was followed by an analysis of maximum and mean Young’s (E) modulus values for MTC (EmaxLR, EmeanLR) and the surrounding thyroid tissues (EmaxSR, EmeanSR), as well as mean E-values (EmeanLRz) for 2 mm region of interest in the stiffest zone of the lesion. The lesions were subject to pathological and/or cytological evaluation. Results: The B-mode assessment showed that all MTCs were hypoechogenic, with no halo sign, and they contained micro- and/ or macrocalcifications. Ill-defined lesion margin were found in 4 out of 6 cancers; 4 out of 6 cancers had a H/W ratio > 1. Heterogeneous echostructure and type III vascularity were found in 5 out of 6 lesions. In the SWE, the mean value of EmaxLR for all of the MTCs was 89.5 kPa and (the mean value of EmaxSR for all surrounding tissues was) 39.7 kPa Mean values of EmeanLR and EmeanSR were 34.7 kPa and 24.4 kPa, respectively. The mean value of EmeanLRz was 49.2 kPa. Conclusions: SWE showed MTCs as stiffer lesions compared to the surrounding tissues. The lesions were qualified for fine needle aspiration biopsy based on B-mode assessment. However, the diagnostic algorithm for MTC is based on the measurement of serum calcitonin levels, B-mode ultrasound and FNAB.

Keywords:
medullary thyroid carcinoma, thyroid, ultrasound, shear wave elastography

Affiliations:
Dobruch-Sobczak K. - IPPT PAN
Gumińska A. - other affiliation
Bakuła-Zalewska E. - Institute of Oncology (PL)
Mlosek K. - Medical University of Warsaw (PL)
Słapa R.Z. - other affiliation
Wareluk P. - Medical University of Warsaw (PL)
Krauze A. - other affiliation
Ziemiecka A. - other affiliation
Migda B. - other affiliation
Jakubowski W. - other affiliation
Dedecjus M. - Institute of Oncology (PL)
27.  Słapa R.Z., Jakubowski W.S., Dobruch-Sobczak K., Kasperlik-Załuska A.A., Standards of ultrasound imaging of the adrenal glands, Journal of Ultrasonography, ISSN: 2084-8404, DOI: 10.15557/JoU.2015.0035, Vol.15, pp.377-387, 2015

Abstract:
Adrenal glands are paired endocrine glands located over the upper renal poles. Adrenal pathologies have various clinical presentations. They can coexist with the hyperfunction of individual cortical zones or the medulla, insufficiency of the adrenal cortex or retained normal hormonal function. The most common adrenal masses are tumors incidentally detected in imaging examinations (ultrasound, tomography, magnetic resonance imaging), referred to as incidentalomas. They include a range of histopathological entities but cortical adenomas without hormonal hyperfunction are the most common. Each abdominal ultrasound scan of a child or adult should include the assessment of the suprarenal areas. If a previously non-reported, incidental solid focal lesion exceeding 1 cm (incidentaloma) is detected in the suprarenal area, computed tomography or magnetic resonance imaging should be conducted to confirm its presence and for differentiation and the tumor functional status should be determined. Ultrasound imaging is also used to monitor adrenal incidentaloma that is not eligible for a surgery. The paper presents recommendations concerning the performance and assessment of ultrasound examinations of the adrenal glands and their pathological lesions. The article includes new ultrasound techniques, such as tissue harmonic imaging, spatial compound imaging, three-dimensional ultrasound, elastography, contrast-enhanced ultrasound and parametric imaging. The guidelines presented above are consistent with the recommendations of the Polish Ultrasound Society.

Keywords:
adrenal glands, adrenal masses, ultrasound, standards

Affiliations:
Słapa R.Z. - other affiliation
Jakubowski W.S. - other affiliation
Dobruch-Sobczak K. - IPPT PAN
Kasperlik-Załuska A.A. - other affiliation
28.  Słapa R.Z., Kasperlik-Załuska A.A., Migda B., Otto M., Dobruch-Sobczak K., Jakubowski W.S., Echogenicity of benign adrenal focal lesions on imaging with new ultrasound techniques – report with pictorial presentation, Journal of Ultrasonography, ISSN: 2084-8404, DOI: 10.15557/JoU.2015.0034, Vol.15, pp.368-376, 2015

Abstract:
Aim: The aim of the research was to assess the echogenicity of benign adrenal focal lesions using new ultrasound techniques. Material and method: 34 benign adrenal masses in 29 patients were analyzed retrospectively. The examinations were conducted using Aplio XG (Toshiba, Japan) ultrasound scanner with a convex probe 1–6 MHz in the B-mode presentation with the combined use of new ultrasound techniques: harmonic imaging and spatial compound sonography. The size of the adrenal tumors, their echogenicity and homogeneity were analyzed. Statistical analysis was conducted using the STATISTICA 10 software. Results: The following adrenal masses were assessed: 12 adenomas, 10 nodular hyperplasias of adrenal cortex, 7 myelolipomas, 3 pheochromocytomas, a hemangioma with hemorrhage and a cyst. The mean diameter of nodular hyperplasia of adrenal cortex was not statistically different from that of adenomas (p = 0.075). The possibility of differentiating between nodular hyperplasia and adenoma using the parameter of hypoechogenicity or homogeneity of the lesion was demonstrated with the sensitivity and specificity of 100% and 41.7%, respectively. The larger the benign adrenal tumor was, the more frequently did it turn out to have a mixed and inhomogenous echogenicity (p < 0.05; ROC areas under the curve: 0.832 and 0.805, respectively). Conclusions: A variety of echogenicity patterns of benign adrenal focal lesions was demonstrated. The image of an adrenal tumor correlates with its size. The ultrasound examination, apart from its indisputable usefulness in detecting and monitoring adrenal tumors, may also allow for the differentiation between benign lesions. However, for lesions found incidentally an algorithm for the assessment of adrenal incidentalomas is applicable, which includes computed tomography and magnetic resonance imaging.

Keywords:
adrenal glands, adrenal masses, ultrasound, echogenicity

Affiliations:
Słapa R.Z. - other affiliation
Kasperlik-Załuska A.A. - other affiliation
Migda B. - other affiliation
Otto M. - other affiliation
Dobruch-Sobczak K. - IPPT PAN
Jakubowski W.S. - other affiliation
29.  Trzebińska A., Dobruch-Sobczak K., Jakubowski W., Jędrzejowski M., Standardy badań ultrasonograficznych Polskiego Towarzystwa Ultrasonograficznego – aktualizacja. Badanie ultrasonograficzne tarczycy oraz biopsja tarczycy pod kontrolą ultrasonografii, Journal of Ultrasonography, ISSN: 2084-8404, DOI: 10.15557/JoU.2014.0005, Vol.14, pp.49-60, 2014

Abstract:
Ultrasonography is a primary imaging technique in patients with suspected thyroid disease. It allows to assess the location, size and echostructures of the thyroid gland as well as detect focal lesions, along with indication of their size, echogenicity, echostructure and vascularity. Based on these features, ultrasound examination allows to predict abnormal focal lesions for biopsy and monitor the biopsy needle track. This paper presents the standards of thyroid ultrasound examination regarding ultrasound apparatus technical requirements, scanning techniques, readings, measurements, and the description of the examination. It discusses the ultrasound features of increased malignancy risk in focal lesions (nodules) found in the thyroid gland. It presents indications for fine needle aspiration biopsy of the thyroid gland for the visibility of single nodules (focal lesions) and numerous lesions as well as discusses contraindications for thyroid biopsy. It describes the biopsy technique, possible complications and rules for post-biopsy monitoring of benign lesions. The paper is an update of the Standards of the Polish Ultrasound Society issued in 2011. It has been prepared on the basis of current literature, taking into account the information contained in the following publications: Thyroid ultrasound examination and Recommendations of the Polish Ultrasound Society for the performance of the FNAB of the thyroid.

Keywords:
ultrasound imaging, thyroid, standards, thyroid diseases, fine needles biopsy

Affiliations:
Trzebińska A. - other affiliation
Dobruch-Sobczak K. - other affiliation
Jakubowski W. - other affiliation
Jędrzejowski M. - other affiliation
30.  Dobruch-Sobczak K., Jędrzejowski M., Jakubowski W., Trzebińska A., Błędy i pomyłki w diagnostyce ultrasonograficznej tarczycy, Journal of Ultrasonography, ISSN: 2084-8404, DOI: 10.15557/JoU.2014.0006, Vol.14, pp.61-73, 2014

Abstract:
Ultrasound examination of the thyroid gland permits to evaluate its size, echogenicity, margins, and stroma. An abnormal ultrasound image of the thyroid, accompanied by other diagnostic investigations, facilitates therapeutic decision-making. The ultrasound image of a normal thyroid gland does not change substantially with patient’s age. Nevertheless, erroneous impressions in thyroid imaging reports are sometimes encountered. These are due to diagnostic pitfalls which cannot be prevented by either the continuing development of the imaging equipment, or the growing experience and skill of the practitioners. Our article discusses the most common mistakes encountered in US diagnostics of the thyroid, the elimination of which should improve the quality of both the ultrasound examination itself and its interpretation. We have outlined errors resulting from a faulty examination technique, the similarity of the neighboring anatomical structures, and anomalies present in the proximity of the thyroid gland. We have also pointed out the reasons for inaccurate assessment of a thyroid lesion image, such as having no access to clinical data or not taking them into account, as well as faulty qualification for a fine needle aspiration biopsy. We have presented guidelines aimed at limiting the number of misdiagnoses in thyroid diseases, and provided sonograms exemplifying diagnostic mistakes.

Keywords:
thyroid, ultrasound imaging, medical mistakes, thyroid diseases, fine needle biopsy

Affiliations:
Dobruch-Sobczak K. - other affiliation
Jędrzejowski M. - other affiliation
Jakubowski W. - other affiliation
Trzebińska A. - other affiliation

List of recent monographs
List of chapters in recent monographs
1. 
Klimonda Z., Dobruch-Sobczak K., Piotrzkowska-Wróblewska H., Tymkiewicz R., Litniewski J., Postępy Akustyki 2016, rozdział: Obrazowanie tłumienia ultradźwięków w tkance nowotworowej, Polskie Towarzystwo Akustyczne, Oddział Warszawski, Warszawa, Poland, pp.39-48, 2016
2. 
Litniewski J., Klimonda Z., Karwat P., Piotrzkowska-Wróblewska H., Dobruch-Sobczak K., Tymkiewicz R., Gambin B., Postępy Akustyki 2016, rozdział: Cancer malignancy sonic markers, Polskie Towarzystwo Akustyczne, Oddział Warszawski, Warszawa, Poland, pp.49-60, 2016

Conference papers
1.  Klimonda Z., Karwat P., Dobruch-Sobczak K., Piotrzkowska-Wróblewska H., Litniewski J., On the assessment of local tumor response to neoadjuvant chemotherapy, IEEE IUS 2023, International Ultrasonics Symposium (IUS) , 2023-09-03/09-08, Monteral (CA), pp.1-4, 2023
2.  Piotrzkowska-Wróblewska H., Dobruch-Sobczak K., Gumowska M., Litniewski J., Changes in quantitative ultrasound imaging as the predictor of response to neoadjuvant chemotherapy in patients with breast cancer, IUS 2022, IEEE, International Ultrasonic Symposium, 2022-10-10/10-13, Wenecja (IT), DOI: 10.1109/IUS54386.2022.9957940., pp.1-4, 2022

Abstract:
The presented study demonstrates the effectiveness of quantitative ultrasound imaging (H-scan ultrasound) in monitoring the breast cancer response to neoadjuvant chemotherapy and predicting pathological response. A group of 40 patients (51 breast tumors) participated in the study. The results showed that QUS imaging was able to distinguish between breast cancer patients responding and not responding to chemotherapy early in the course of treatment. Analysis of the percentage changes in red in the parametric images showed that this parameter can predict the response to treatment of patients with the area under the receiver operational characteristics (ROC) curve of 0.61, 0.70, 0.83, and 0.86, respectively, one week after 1st 2nd , 3rd and 4th dose of treatment.

Keywords:
breast cancer, neoadjuvant chemotherapy, ultrasound, H-scan ultrasounds.

Affiliations:
Piotrzkowska-Wróblewska H. - IPPT PAN
Dobruch-Sobczak K. - IPPT PAN
Gumowska M. - other affiliation
Litniewski J. - IPPT PAN
3.  Karwat P., Klimonda Z., Piotrzkowska-Wróblewska H., Dobruch-Sobczak K., Litniewski J., Quantitative ultrasound examination of peritumoral tissue improves classification of breast lesions, IUS 2019, IEEE, International Ultrasonics Symposium, 2019-10-06/10-09, Glasgow (GB), pp.1509-1511, 2019
4.  Klimonda Z., Karwat P., Piotrzkowska-Wróblewska H., Dobruch-Sobczak K., Litniewski J., Ultrasound scattering statistics predicts the result of neoadjuvant chemotherapy of breast tumors at an early stage of treatment, IUS 2019, IEEE, International Ultrasonics Symposium, 2019-10-06/10-09, Glasgow (GB), pp.1512-1514, 2019
5.  Klimonda Z., Karwat P., Dobruch-Sobczak K., Piotrzkowska-Wróblewska H., Litniewski J., Assessment of a breast cancer response to neoadjuvant chemotherapy using backscatter ultrasound statistics, 2019 ICU Bruges, 2019 International Congress on Ultrasonics, 2019-09-03/09-06, Bruges (BE), DOI: 10.1121/2.0001104, Vol.38, No.1, pp.020003-1-5, 2019
6.  Byra M., Sznajder T., Korzinek D., Piotrzkowska-Wróblewska H., Dobruch-Sobczak K., Nowicki A., Marasek K., Impact of Ultrasound Image Reconstruction Method on Breast Lesion Classification with Deep Learning. Pattern Recognition and Image Analysis, IbPRIA 2019, 9th Iberian Conference on Pattern Recognition and Image Analysi, 2019-07-01/07-04, Madryt (ES), pp.41-52, 2019

Abstract:
In this work we investigate the usefulness and robustness of transfer learning with deep convolutional neural networks (CNNs) for breast lesion classification in ultrasound (US). Deep learning models can be vulnerable to adversarial examples, engineered input image pixel intensities perturbations that force models to make classification errors. In US imaging, distribution of US image pixel intensities relies on applied US image reconstruction algorithm. We explore the possibility of fooling deep learning models for breast mass classification by modifying US image reconstruction method. Raw radio-frequency US signals acquired from malignant and benign breast masses were used to reconstruct US images, and develop classifiers using transfer learning with the VGG19, InceptionV3 and InceptionResNetV2 CNNs. The areas under the receiver operating characteristic curve (AUCs) obtained for each deep learning model developed and evaluated using US images reconstructed in the same way were equal to approximately 0.85, and there were no associated differences in AUC values between the models (DeLong test p-values > 0.15). However, due to small modifications of the US image reconstruction method the AUC values for the models utilizing the VGG19, InceptionV3 and InceptionResNetV2 CNNs significantly decreased to 0.592, 0.584 and 0.687, respectively. Our study shows that the modification of US image reconstruction algorithm can have significant negative impact on classification performance of deep models. Taking into account medical image reconstruction algorithms may help develop more robust deep learning computer aided diagnosis systems.

Keywords:
Adversarial attacks, Breast lesion classification, Computer aided diagnosis, Deep learning, Robustness, Ultrasound imaging, Transfer learning

Affiliations:
Byra M. - IPPT PAN
Sznajder T. - other affiliation
Korzinek D. - Polish-Japanese Academy of Information Technology (PL)
Piotrzkowska-Wróblewska H. - IPPT PAN
Dobruch-Sobczak K. - IPPT PAN
Nowicki A. - IPPT PAN
Marasek K. - Polish-Japanese Academy of Information Technology (PL)
7.  Dobruch-Sobczak K., Piotrzkowska-Wróblewska H., Klimonda Z., Gumowska M.E., Litniewski J., Ultrasound echogenicity reveals the response of breast cancer to chemotherapy, ECR 2019, EUROPEAN CONGRESS OF RADIOLOGY, 2019-02-27/03-03, Wiedeń (AT), DOI: 10.26044/ecr2019/C-1007, pp.1-15, 2019
8.  Piotrzkowska-Wróblewska H., Klimonda Z., Dobruch-Sobczak K., Karwat P., Secomski W., Litniewski J., Quantitative Ultrasound for Chemotherapy Monitoring, IEEE 2018, IEEE Joint Conference - Acoustics, 2018-09-11/09-14, Ustka (PL), DOI: 10.1109/ACOUSTICS.2018.8502336, pp.268-271, 2018

Abstract:
Neoadjuvant chemotherapy (NAC) is used in breast cancer patients to reduce tumor size, decrease the risk of local recurrence, and diminish the likelihood of metastases, all of which reduce patient mortality. Assessment of the response to NAC at an early stage of treatment allows therapy to be personalized. The quantitative ultrasound method is a novel diagnostic approach with great potential to improve outcomes for breast cancer patients. The aim of this study was to analyze the variability of the integrated backscatter coefficient (IBSC) in the context of the assessment of changes in tumor tissue structure resulting from chemotherapy, and to evaluate use of IBSC to predict the effectiveness of treatment. Ultrasound data (B-mode images and raw ultrasonic radio frequency signals RF) were collected from cancerous tumors from patients intended to NAC before starting treatment and a week after each chemotherapy dose. Data were processed to generate IBSC maps and to determine IBSC mean values. The assessment of tumors using IBSC, in comparison with histopathological verification, showed that IBSC changes can be associated with changes which tumor structure changes during NAC. IBSC analysis correlated better with the results of histopathological verification than B-mode imaging.

Affiliations:
Piotrzkowska-Wróblewska H. - IPPT PAN
Klimonda Z. - IPPT PAN
Dobruch-Sobczak K. - IPPT PAN
Karwat P. - IPPT PAN
Secomski W. - IPPT PAN
Litniewski J. - IPPT PAN
9.  Klimonda Z., Dobruch-Sobczak K., Piotrzkowska-Wróblewska H., Karwat P., Litniewski J., Quantitative Ultrasound of Tumor Surrounding Tissue for Enhancement of Breast Cancer Diagnosis, IWBBIO 2018, 6th International Work-Conference, 2018-04-25/04-27, Granada (ES), DOI: 10.1007/978-3-319-78759-6_18, Vol.10814, pp.186-197, 2018

Abstract:
Breast cancer is one of the leading causes of cancer-related death in female patients. The quantitative ultrasound techniques being developed recently provide useful information facilitating the classification of tumors as malignant or benign. Quantitative parameters are typically determined on the basis of signals scattered within the tumor. The present paper demonstrates the utility of quantitative data estimated based on signal backscatter in the tissue surrounding the tumor. Two quantitative parameters, weighted entropy and Nakagami shape parameter were calculated from the backscatter signal envelope. The ROC curves and the AUC parameter values were used to assess their ability to classify neoplastic lesions. Results indicate that data from tissue surrounding the tumor may characterize it better than data from within the tumor. AUC values were on average 18% higher for parameters calculated from data collected from the tissue surrounding the lesion than from the data from the lesion itself.

Keywords:
uantitative ultrasound, Tissue characterisation, Tumor classification

Affiliations:
Klimonda Z. - IPPT PAN
Dobruch-Sobczak K. - IPPT PAN
Piotrzkowska-Wróblewska H. - IPPT PAN
Karwat P. - IPPT PAN
Litniewski J. - IPPT PAN
10.  Byra M., Piotrzkowska-Wróblewska H., Dobruch-Sobczak K., Nowicki A., Combining Nakagami imaging and convolutional neural network for breast lesion classification, IUS 2017, IEEE International Ultrasonics Symposium, 2017-09-06/09-09, Washington (US), DOI: 10.1109/ULTSYM.2017.8092154, pp.1-4, 2017

Abstract:
In this paper we propose a computer-aided diagnosis system for the breast lesion classification. Our approach is based on quantitative ultrasound and deep learning. We used the Nakagami imaging to create parametric maps of breast lesions that illustrate tissue scattering properties. For this task the sliding window technique was applied. The Nakagami parameter was calculated using the maximum likelihood estimator. Next, we used the Nakagami parameter maps to train a convolutional neural network. Classification performance was evaluated by 5-fold cross-validation. We obtained the area under the receiver operating characteristic curve equal to 0.91. The results showed that our approach is useful to distinguishing between malignant and benign breast lesions. The proposed method serves as a general approach for tissue characterization and differentiation. The Nakagami parameter used in this study can be replaced with other QUS parameters and the neural network can be trained in a similar fashion.

Keywords:
Nakagami imaging, quantitative ultrasound, convolutional neural networks, breast lesion classification, deep learning

Affiliations:
Byra M. - IPPT PAN
Piotrzkowska-Wróblewska H. - IPPT PAN
Dobruch-Sobczak K. - IPPT PAN
Nowicki A. - IPPT PAN
11.  Nowicki A., Piotrzkowska H., Dobruch-Sobczak K., Litniewski J., Byra M., Gambin B., Kruglenko E., Differentiation of normal tissue and tissue lesions using statistical properties of backscattered ultrasound in breast, IUS 2015, IEEE International Ultrasonics Symposium, 2015-10-21/10-24, Taipei (TW), DOI: 10.1109/ULTSYM.2015.0417, pp.P1B6-15-4, 2015

Abstract:
The aim of the study was finding the relationship between BIRADS classification combined with envelope K and Nakagami statistics of the echoes backscattered in the breast tissue in vivo and the histological data. 107 breast lesions were examined. Both, the RF echo-signal and B-mode images from the lesions and surrounding tissue were recorded. The analysis method was based on the combining data from BIRADS classifications and both distributions parameters. 107 breasts lesions - 32 malignant and 75 benign - were examined. When only BIRADS classification was used all malignant lesions were diagnosed correctly, however 34 benign lesions were sent for the biopsy unnecessarily. For K distribution the sensitivity and specificity were 78.13%, and 86.67% while for Nakagami statistics the sensitivity and specificity were 62.50% and 93.33%, respectively. Combined K and BIRADS resulted in sensitivity of 96.67% and specificity 60%. Combined BIRADS (3/4a cut-off) plus Nakagami statistics showed 100% of sensitivity with specificity equal 57.33%, decreasing the number of lesions which were biopsied from 34 to 28.

Keywords:
breast cancer, quantitative ultrasound, BIRADS

Affiliations:
Nowicki A. - IPPT PAN
Piotrzkowska H. - IPPT PAN
Dobruch-Sobczak K. - IPPT PAN
Litniewski J. - IPPT PAN
Byra M. - IPPT PAN
Gambin B. - IPPT PAN
Kruglenko E. - IPPT PAN
12.  Byra M., Nowicki A., Piotrzkowska H., Dobruch-Sobczak K., Litniewski J., Correcting the influence of tissue attenuation on Nakagami distribution shape parameter estimation, IUS 2015, IEEE International Ultrasonics Symposium, 2015-10-21/10-24, Taipei (TW), DOI: 10.1109/ULTSYM.2015.0408, pp.P1B6-3-4, 2015

Abstract:
Nakagami distribution is used to model the statistical properties of backscattered echoes in tissue. The proper estimate requires the compensation of attenuation along each scanning line. Attenuation of the wave results in decreasing of the envelope mean intensity with depth what modifies the Nakagami scale parameter. This phenomenon violates the assumption that envelope samples within region of interest are identically distributed and disrupts estimation. Here, we investigate the influence of wave attenuation on Nakagami shape parameter estimators for various scattering scenarios, attenuation coefficients and region of interest size. Three methods are proposed to solve this issue. Scans of a thyroid and of a breast lesion are analyzed. It was found that proposed methods improved the estimation, especially when larger regions were used to collect envelope samples.

Keywords:
ultrasound, breast cancer, Nakagami distribution

Affiliations:
Byra M. - IPPT PAN
Nowicki A. - IPPT PAN
Piotrzkowska H. - IPPT PAN
Dobruch-Sobczak K. - IPPT PAN
Litniewski J. - IPPT PAN
13.  Piotrzkowska H., Nowicki A., Litniewski J., Gambin B., Dobruch-Sobczak K., Breast carcinoma tissues characterization using statistics of ultrasonic backscatter, FA2014, 7th FORUM ACUSTICUM 2014, 2014-09-07/09-12, Kraków (PL), No.SS27_7, pp.1-9, 2014

Abstract:
The Ultrasonix SonixTouch scanner with the special RF block was used to collect Bmode images together with appropriate RF echoes from the pathological and healthy breasts regions of patients with diagnosed malignant and benign breast lesions. The RF data were processed for the statistics of the backscattered echo signals assessment (K distribution and effective density of scatterers – M and Nakagami distribution and its shape parameter m). The comparison of signals recorded from malignant and healthy tissues showed, that in 80% of examined cases the values of the statistical parameters M were higher for carcinomas tissues than for healthy tissue. Beside of that in the case of benign lesions obtained results was able to distinguish the fibroadenoma from the other with probability of 75%.

Keywords:
quantitative ultrasound, breast cancer, statistics

Affiliations:
Piotrzkowska H. - IPPT PAN
Nowicki A. - IPPT PAN
Litniewski J. - IPPT PAN
Gambin B. - IPPT PAN
Dobruch-Sobczak K. - other affiliation

Conference abstracts
1.  Pawłowska A., Żołek N., Dobruch-Sobczak K., Klimonda Z., Piotrzkowska-Wróblewska H., Litniewski J., The outcome of breast chemotherapy based on Gray Relational Coefficient of ultrasound images, XXII Polish Conference on Biocybernetics and Biomedical Engineering, 2021-05-19/05-21, Warszawa (PL), pp.105, 2021
2.  Dobruch-Sobczak K., Piotrzkowska-Wróblewska H., Klimonda Z., Karwat P., Litniewski J., Roszkowska-Purska K., Markiewicz-Grodzicka E., Quantitative ultrasound parameters assessment of advanced breast cancer in evaluation the response to neoadjuvant chemotherapy, 11TH EUROPEAN BREAST CANCER CONFERENCE, 2018-03-21/03-23, Barcelona (ES), DOI: 10.1016/S0959-8049(18)30674-9, Vol.92, pp.149-150, 2018

Abstract:
Background: Monitoring of response to neoadjuvant chemotherapy (NAC) in advanced breast cancer is crucial for assessing the effectiveness of the treatment and overall survival. The purpose of this study was to investigate the ability of classical ultrasound (US) examination and quantitative ultrasound (QU) parameters to predict the therapy response comparing to histology results after surgical treatment. Material and Methods: Two ultrasound backscatter parameters: the integrated backscatter coefficient, (IBSC) and shape parameter (M) of the homodyned K distribution, were estimated from ultrasonic radiofrequency (RF) signals. Sixteen patient with 22 breast cancer tumor treated with NAC sequential Anthracyclines and Taxanes were prospectively assessed. Data were acquired using 5–14 MHz array transducer, pre-chemotherapy, and four times during treatment (one week after the subsequent courses). The US results were compared with histological response analyzing the stromal changes and the cellularity of the tumor. Results: An increase in IBSC and decrease M parameters was observed in 80% of tumors with complete response after chemotherapy. It correlates with increasing the stromal elements, fibrosis, and elastosis. In patients with partial response, the parameters IBSC and M parameters did not change during subsequent cycles of treatment and allow predicting partial response in 70% of tumors. In pathological results, a similar cluster of cells without fibrosis and elastosis were observed. Conclusions: Ultrasound parameters derived from the RF data give the promise to predict the tumor response to NAC and better personalize the therapy using US QU examination. This study was supported by the National Science Centre, Poland, grant 2016/23/B/ST8/03391. No conflict of interest

Affiliations:
Dobruch-Sobczak K. - other affiliation
Piotrzkowska-Wróblewska H. - IPPT PAN
Klimonda Z. - IPPT PAN
Karwat P. - IPPT PAN
Litniewski J. - IPPT PAN
Roszkowska-Purska K. - other affiliation
Markiewicz-Grodzicka E. - Oncology Institute (PL)
3.  Litniewski J., Klimonda Z., Karwat P., Piotrzkowska-Wróblewska H., Dobruch-Sobczak K., Tymkiewicz R., Gambin B., Cancer Malignancy Sonic Markers, OSA 16, LXIII Otwarte Seminarium z Akustyki, 2016-09-13/09-16, Białowieża (PL), DOI: 10.1515/aoa-2016-0059, No.3, pp.622, 2016
4.  Klimonda Z., Dobruch-Sobczak K., Piotrzkowska-Wróblewska H., Tymkiewicz R., Litniewski J., Ultrasound attenuation imaging of tumor tissue, OSA 16, LXIII Otwarte Seminarium z Akustyki, 2016-09-13/09-16, Białowieża (PL), DOI: 10.1515/aoa-2016-0059, pp.619-620, 2016

Keywords:
attenuation estimation, parametric imaging

Affiliations:
Klimonda Z. - IPPT PAN
Dobruch-Sobczak K. - IPPT PAN
Piotrzkowska-Wróblewska H. - IPPT PAN
Tymkiewicz R. - IPPT PAN
Litniewski J. - IPPT PAN
5.  Nowicki A., Dobruch-Sobczak K., Piotrzkowska H., Litniewski J., Gambin B., Roszkowska K., Chrapowicki E., Clinical Validation of the Statistical Analysis of US RF Signals in Differentiation of the Breast Lesions, AIUM 2015, Ultrasound in Medicine and Biology Annual Convention, 2015-03-21/03-25, Lake Buena Vista (US), DOI: 10.1016/j.ultrasmedbio.2014.12.403, Vol.41, No.4S, Special issue: 2015 AIUM Annual Convention and Preconvention Program Hosting WFUMB Congress, ABSTRACT 2088809, pp.S98-S99, 2015

Abstract:
The scattering is the fundamental phenomena used for US imaging of specific organs. In this study the method searching for best fitted statistical distribution of the acquired echoes from the breast tissue is discussed, especially addressing the ‘‘effective’’ number of scatterers. The aim of the study was finding the relationship between the specific properties of statistics of envelope of the ultrasonic echoes backscattered in the breast tissue in vivo, and its morphological properties for normal tissue and the pathological lesions.
Methods: 72 patients with 83 suspicious breast lesions (BIRADS 3, 4, 5) were examined. The analysis method was based on the parametric imaging representing a map of local statistical properties of the scattering of ultrasound waves in normal and pathological tissues. Both, the RF echo-signal and B-mode images from the lesions and surrounding tissue were recorded. The statistics of backscattered speckle-like echoes envelopes were modelled using K and Nakagami distributions. For all lesions the set of sub-ROIs covering full lesion was chosen. The statistical analysis was done for every sub-ROI separately. The shape parameters were calculated including the compensation for TGC applied and for the attenuation.
Results: The evaluation of all 83 breasts lesions revealed 23 malignant and 60 benign lesions. Typically, both, shape parameters for malignant lesions were statistically larger than for surrounding tissue. On the other hand, the benign lesions revealed much larger variance of the parameters comparing to the surrounding and malignant tissue. The sensitivity and specificity of B-mode imaging with the cut-off points BIRADS-4a/4b were 93%, 86%. For K and Nakagami distributions obtained sensitivity and specificity were respectively 85% and 91%.
Conclusions: The quantitative measurements of the breast tissue backscattering statistical properties improve the specificity of B-mode examinations and can be helpful in the differentiation the character of the breast lesions. It was proved that the range of the shape parameters appears to be rather large and can not be interpreted without taking into account the corresponding values in the surrounding ‘‘normal’’ tissue.

Keywords:
breast cancer, ultrasound, RF echo-signal

Affiliations:
Nowicki A. - IPPT PAN
Dobruch-Sobczak K. - IPPT PAN
Piotrzkowska H. - IPPT PAN
Litniewski J. - IPPT PAN
Gambin B. - IPPT PAN
Roszkowska K. - other affiliation
Chrapowicki E. - Center of Oncology Memorial Institute (PL)
6.  Dobruch-Sobczak K., Gumińska A., Bakuła-Zalewska E., Kaczor A., Piotrzkowska H., Jakubowski W., Nowicki A., Dedecjus M., Zastosowanie elastografii fali poprzecznej w diagnostyce raka rdzeniastego tarczycy, V Konferencja Rak Tarczycy i inne nowotwory zlośliwe układu wydzielania wewnętrznego, 2015-11-14/11-17, Wisła (PL), DOI: 10.15557/JoU.2015.003, Vol.66, No.15, pp.358-367, 2015

Abstract:
Elastografia fali poprzecznej jest nowoczesną metodą oceny sztywności tkanek. Obserwuje się wzrost zainteresowania tą techniką w różnicowaniu charakteru zmian ogniskowych w tarczycy również w diagnostyce przedoperacyjnej. Cel pracy: Celem niniejszej pracy była ocena klinicznej przydatności elastografi i fali poprzecznej w diagnostyce raka rdzeniastego tarczycy (RRT). Materiał i metoda: W badanej grupie 139 pacjentów stwierdzono 169 zmian ogniskowych, a u 4 pacjentów (średni wiek: 45 lat) rozpoznano 6 RRT. Wykonano USG B-mode oraz elastografię fali poprzecznej aparatem Aixplorer (Super-Sonic, Aix-en-Provence), głowicą liniową o częstotliwości 4–15 MHz. W USG oceniano echogeniczność i echo strukturę zmian, ich brzegi, objaw „halo”, stosunek wysokości dogłębokości (W/G), obecność zwapnień oraz wzorzec unaczynienia. Następnie analizowano: maksymalne i średnie wartości modułu Younga (E) dla największego ROI dla RRT (EmaxLR, EmeanLR ) oraz dla otaczających tkanek w miąższu gruczołu (EmaxSR, EmeanSR), a także średnie wartości E (EmeanLRz) dla 2 mm obszaru zainteresowania z najsztywniejszej części zmiany. Zmiany zweryfikowano histopatologicznie i/lub cytologicznie. Wyniki: W ocenie B-mode wszystkie RRT były hipoechogeniczne, bez obecności objawu „halo”, oraz zawierał y mikro- i/lub makrozwapnienia. Nieostre granice zmiany obecne były w 4 z 6 raków. Wartość ilorazu WG >1 dotyczył a 4 na 6 zmian. Niejednorodną echo strukturę oraz typ III unaczynienia stwierdzono w 5 na 6 zmian. W SWE średnia wartość E maxLR w obrębie RRT wynosił a 89,5 kPa, w otoczeniu – 39,7 kPa. Średnie wartości E meanLR, E meanSR wynosił y odpowiednio: 34,6 kPa i 24,4 kPa. Wartość średnia E meanLRz=49,2 kPa. Wnioski: W SWE RRT przedstawiały się jako zmiany sztywniejsze w porównaniu z otaczającymi tkankami. W ocenie B-mode spełniały wskazania do biopsji spiracyjnej cienkoigłowej. Jednak algorytm diagnostyczny RRT opiera się na pomiarze stężenia kalcytoniny w surowicy krwi, ocenie USG B-mode oraz biopsji.

Keywords:
rak rdzeniasty, tarczyca, badanie USG, sonoelastografia fali poprzecznej

Affiliations:
Dobruch-Sobczak K. - IPPT PAN
Gumińska A. - other affiliation
Bakuła-Zalewska E. - Institute of Oncology (PL)
Kaczor A. - other affiliation
Piotrzkowska H. - IPPT PAN
Jakubowski W. - other affiliation
Nowicki A. - IPPT PAN
Dedecjus M. - Institute of Oncology (PL)
7.  Dobruch-Sobczak K., Gumińska A., Bakuła-Zalewska E., Piotrzkowska H., Mlosek K., Słapa R.Z., Wareluk P., Migda B., Olszewski W., Jakubowski W., Nowicki A., Dedecjus M., Wartość sonoelastografii fali poprzecznej (SWE) w szacowaniu ryzyka złośliwości zmian ogniskowych tarczycy, V Konferencja Rak Tarczycy i inne nowotwory zlośliwe układu wydzielania wewnętrznego, 2015-11-14/11-17, Wisła (PL), Vol.66, pp.1, 2015
8.  Gambin B., Kruglenko E., Byra M., Nowicki A., Piotrzkowska H., Dobruch-Sobczak K., Changes in ultrasound echoes of a breast tissue in vivo after exposure to heat - a case study, PCM-CMM 2015, 3rd Polish Congress of Mechanics and 21st Computer Methods in Mechanics, 2015-09-08/09-11, Gdańsk (PL), pp.217-218, 2015

Abstract:
A B-mode ultrasonography provides structural information on the tissue under investigation encoding the echo strength in gray scale in a two-dimensional image. Interpretation of the B-mode image of breast tissue is done by a physician. The analysis of statistical properties of backscattered RF signal has been recently applied successfully to distinct healthy tissue from tissue lesions regions as a new method of quantitative ultrasound (QUS). Up till now, the most reliable results were obtained for liver and renal tissue lesions, because their normal, healthy structures are nearly homogeneous while a heterogeneous breast tissue classification is still an open issue. The recent study revealed that the medium contraction and expansion induced by a temperature change may cause variations in the relative position of scatterers in a tissue. We have developed a new procedure of heating the patient breast and allowing to observe and record in vivo the influence of temperature changes on a B-mode image and properties of unprocessed radio frequency (RF) backscattered echoes. The initial, feasibility studies of influence of the temperature increase in breast tissue on the intensity, spectrum and statistics of ultrasonic echoes will be discussed.

Keywords:
breast tissue, RF signal, backscattered signal amplitude statistics, spectral properties

Affiliations:
Gambin B. - IPPT PAN
Kruglenko E. - IPPT PAN
Byra M. - IPPT PAN
Nowicki A. - IPPT PAN
Piotrzkowska H. - IPPT PAN
Dobruch-Sobczak K. - IPPT PAN

Category A Plus

IPPT PAN

logo ippt            Pawińskiego 5B, 02-106 Warsaw
  +48 22 826 12 81 (central)
  +48 22 826 98 15
 

Find Us

mapka
© Institute of Fundamental Technological Research Polish Academy of Sciences 2024