Institute of Fundamental Technological Research
Polish Academy of Sciences

Partners

I. Brcic


Recent publications
1.  Marek R., Ćwieka H., Donouhue N., Holweg P., Moosmann J., Beckmann F., Brcic I., Schwarze U. Y., Iskhakova K., Chaabane M., Sefa S., Zeller-Plumhoff B., Weinberg A., Willumeit-Römer R., Sommer N., Degradation behavior and osseointegration of Mg-Zn-Ca screws in different bone regions of growing sheep, regenerative biomaterials, ISSN: 2056-3418, DOI: 10.1093/rb/rbac077, Vol.rbac077, pp.26-60, 2022

Abstract:
Magnesium (Mg)-based implants are highly attractive for the orthopedic field and may replace titanium (Ti) as support for fracture healing. To determine the implant-bone-interaction in different bony regions, we implanted Mg-based alloy ZX00 (Mg < 0.5 Zn < 0.5 Ca, in wt%) and Ti-screws into the distal epiphysis and distal metaphysis of sheep tibiae. The implant degradation and osseointegration were assessed in vivo and ex vivo after 4, 6 and 12 weeks, using a combination of clinical computed tomography (cCT), medium-resolution micro CT (µCT) and high-resolution synchrotron radiation µCT (SRµCT). Implant volume loss, gas formation, and bone growth were evaluated for both implantation sites and each bone region independently. Additionally, histological analysis of bone growth was performed on embedded hard-tissue samples. We demonstrate that in all cases, the degradation rate of ZX00-implants ranges between 0.23-0.75 mm/year. The highest degradation rates were found in the epiphysis. Bone-to-implant-contact varied between the time points and bone types for both materials. Mostly, bone-volume-to-total-volume was higher around Ti-implants. However, we found an increased cortical thickness around the ZX00-screws when compared to the Ti-screws. Our results showed the suitability of ZX00-screws for implantation into the distal meta- and epiphysis

Keywords:
Biodegradable implants,Magnesium-based alloys,Computed tomography,Mg-Zn-Ca,Sheep,Histology

Affiliations:
Marek R. - other affiliation
Ćwieka H. - IPPT PAN
Donouhue N. - other affiliation
Holweg P. - other affiliation
Moosmann J. - other affiliation
Beckmann F. - other affiliation
Brcic I. - other affiliation
Schwarze U. Y. - other affiliation
Iskhakova K. - other affiliation
Chaabane M. - other affiliation
Sefa S. - other affiliation
Zeller-Plumhoff B. - other affiliation
Weinberg A. - other affiliation
Willumeit-Römer R. - other affiliation
Sommer N. - other affiliation

Category A Plus

IPPT PAN

logo ippt            Pawińskiego 5B, 02-106 Warsaw
  +48 22 826 12 81 (central)
  +48 22 826 98 15
 

Find Us

mapka
© Institute of Fundamental Technological Research Polish Academy of Sciences 2024