Katarzyna Majka

Military Medical Institute (PL)

Ostatnie publikacje
1.  Majka K., Lejkowski W., Pepłoński A., Grycewicz T., Krupienicz A., Dobrowolski.P., Olszewski R., The use of an electronic stethoscope with dedicated software for cardiovascular screening of patients prepared for hip replacement, Academia Journal of Scientific Research, ISSN: 2315-7712, DOI: 10.15413/ajsr.2020.0110, Vol.8, No.6, pp.207-217, 2020

Streszczenie:
Cardiovascular disease (CVD) is one of the major causes of perioperative complications. Screening of patients referred to major surgery is a costly and time and resources- consuming process. The study aimed to assess the usefulness of an electronic stethoscope with dedicated analytical software operated by a nurse for detecting heart disease in patients prepared for major orthopedic surgery. The study group consisted of 137 patients aged (46 – 91) with defined cardiovascular diseases qualified for hip or knee replacement surgery and 94 healthy age-matched volunteers. Heart auscultation with Littmann lectronic stethoscope using Littmann® StethAssist™ Heart and Lung Sound Visualization Software software was conducted and analyzed by a trained nurse. The signal recorded was analyzed by the blinded researcher using dedicated custom- made algorithm. Finally, 91 signals (52 CVD (+) patients, 39 CVD (-) patients) were analyzed. Eventually a classifier with a sensitivity of 92% and a specificity of 97% was obtained in a group. The global accuracy of the classifier was 95%. Heart auscultation by nursing staff using Littmann® StethAssist™ Heart and Lung Sound Visualization Software with dedicated custom- made can be cheap and noninvasive method of identifying patients with cardiovascular disease made algorithm for arthroplasty.

Słowa kluczowe:
electronic stethoscope, heart auscultation, nurse, arthroplasty, cardiovascular disease

Afiliacje autorów:
Majka K. - Military Medical Institute (PL)
Lejkowski W. - Centralny Wojskowy Ośrodek Metrologii (PL)
Pepłoński A. - Military Medical Institute (PL)
Grycewicz T. - Medical University of Lodz (PL)
Krupienicz A. - Medical University of Warsaw (PL)
Dobrowolski.P. - Military University of Technology (PL)
Olszewski R. - IPPT PAN
2.  Stasiakiewicz P., Dobrowolski A.P., Olszewski R., Gałązka-Świderek N., Targowski T., Skoczylas A., Majka K., Lejkowski W., Klasyfikacja szmerów oddechowych – badania pilotażowe, ELEKTRONIKA - KONSTRUKCJE, TECHNOLOGIE, ZASTOSOWANIA, ISSN: 0033-2089, DOI: 10.15199/13.2019.2.1, Vol.2, pp.4-12, 2019

Streszczenie:
Układ oddechowy pacjenta jest początkowo diagnozowany przy zastosowaniu stetoskopu. Osłuchowa interpretacja zjawisk fizycznych jest skomplikowana i wymaga od lekarza doświadczenia oraz predyspozycji. W niniejszym artykule zaprezentowano system pomiarowy i oprogramowanie badawcze, a także proces generacji cech dystynktywnych szmerów oddechowych różnicujących przypadki chorobowe od zdrowych. Wybrane reprezentacje stanowią obiecującą podstawę do opracowania systemu klasyfikującego wspierającego proces diagnostyczny

Słowa kluczowe:
szmery oddechowe, klasyfikacja, cyfrowe przetwarzanie sygnałów

Afiliacje autorów:
Stasiakiewicz P. - Military University of Technology (PL)
Dobrowolski A.P. - Military University of Technology (PL)
Olszewski R. - IPPT PAN
Gałązka-Świderek N. - Regional Hospital (PL)
Targowski T. - National Institute of Geriatrics, Rheumatology and Rehabilitation (PL)
Skoczylas A. - National Institute of Geriatrics, Rheumatology and Rehabilitation (PL)
Majka K. - Military Medical Institute (PL)
Lejkowski W. - Centralny Wojskowy Ośrodek Metrologii (PL)
3.  Majka K., Krupienicz A., Olszewski R., Telepielęgniarstwo w ortopedii, Medycyna Ogólna i Nauki o Zdrowiu, ISSN: 2083-4543, DOI: 10.26444/monz/75509, Vol.23, No.2, pp.94-97, 2017

Streszczenie:
Wprowadzenie i cel pracy. Rozwój technologii informacyjno-komunikacyjnej może doprowadzić do poprawy sytuacji w służbie zdrowia. Telepielęgniarstwo pozwoli na rozszerzenie praktyki pielęgniarskiej oraz wielu funkcji takich jak: opiekuńczo-pielęgnacyjna, profilaktyczna, diagnostyczna, rehabilitacyjna i związana z promocją zdrowia. Celem pracy jest ukazanie telepielęgniarstwa w ortopedii, a także zaprezentowanie wielu korzyści, jakie niesie zarówno dla pacjenta, jak i dla personelu medycznego. Skrócony opis stanu wiedzy. Starzejące się społeczeństwo potrzebuje zarówno wykwalifikowanego personelu pielęgniarskiego, jak i możliwości uzyskania szybkiej konsultacji lekarskiej i pielęgniarskiej. Udzielanie wskazówek, porad i opieki pielęgniarskiej przez pielęgniarki specjalistki w swej profesji m.in. za pomocą wideokonferencji przysporzy znaczących korzyści zarówno pacjentom, lekarzom, pielęgniarkom, jak i rehabilitantom. Podsumowanie. Wdrożenie wirtualnych wizyt może doprowadzić do poprawy sytuacji w ochronie zdrowia. Telepielęgniarstwo rozszerzyłoby kompetencje pielęgniarki, a także podniosłoby jakość świadczonych przez nie usług. Być może zatrzymałoby również emigrację zarobkową pielęgniarek w Polsce.

Słowa kluczowe:
telepielęgniarstwo, ortopedia, edukacja pacjenta, nowe technologie, kształcenie, niedobór personelu pielęgniarskiego

Afiliacje autorów:
Majka K. - Military Medical Institute (PL)
Krupienicz A. - Medical University of Warsaw (PL)
Olszewski R. - IPPT PAN
6p.

Prace konferencyjne
1.  Secomski W., Klimonda Z., Majka K., Olszewski R., Nowicki A., Sonothrombolysis - Dissolving Thrombi by Interaction of the Drug and Ultrasound, IEEE 2018, IEEE Joint Conference - Acoustics, 2018-09-11/09-14, Ustka (PL), DOI: 10.1109/ACOUSTICS.2018.8502412, pp.290-293, 2018

Streszczenie:
Under the influence of pathological changes, the blood coagulates inside the blood vessel, creating a thrombus. The thrombus dissolution process is called thrombolysis. The aim of the study is to evaluate the thrombolysis process by the interaction of the thrombolitic drug and ultrasound. The clot dissolution process was analyzed in a specially designed, transparent for ultrasound parallel plate flow chamber. Inside, a freshly coagulated human blood sample was exposed to ultrasound. A liquid containing the tissue plasminogen activator drug in a concentration of 10 μg/ml passed around the sample. The liquid flow was forced by a peristaltic pump. The source of ultrasound was a 1 MHz flat ultrasonic transducer with a 25 mm diameter. The transducer radiated a 1000 periods burst, repeated every 2500 periods and space averaged time averaged intensities of 0.2-1.6 W/cm2. The efficacy of thrombus dissolution was observed by means of a designed parallel plate flow chamber and the time of thrombus complete dissolution was measured. The best result for the 1 MHz frequency and space averaged time averaged intensity of 1.6 W/cm2 was recorded, where the thrombus was dissolved within 5.5 minutes.

Słowa kluczowe:
ultrasound, blood, thrombus, thrombolysis, parallel plate flow chamber

Afiliacje autorów:
Secomski W. - IPPT PAN
Klimonda Z. - IPPT PAN
Majka K. - Military Medical Institute (PL)
Olszewski R. - IPPT PAN
Nowicki A. - IPPT PAN
20p.
2.  Secomski W., Klimonda Z., Majka K., Olszewski R., Nowicki A., Microscopic examination of the sonothrombolysis process inside the transparent to ultrasound parallel plate flow chamber, IUS 2018, IEEE International Ultrasonics Symposium, 2018-10-22/10-25, KOBE (JP), DOI: 10.1109/ULTSYM.2018.8580087, pp.1-4, 2018

Streszczenie:
Parallel plate flow chambers are widely used for cell research in conditions of constant or pulsatile liquid flow. They are also used to analyze the formation of thrombi. The authors designed a flow chamber that is transparent to ultrasound, thus enabling the microscopic observation of the thrombus dissolution process by interaction of drug, microbubbles and ultrasound in real time, in-vitro. Sonothrombolysis was performed at 1 MHz and 3.3 MHz ultrasound frequencies, at space-averaged and time-averaged intensities ISATA of 0.2 – 1.6 W/cm2. 1 mm thick slices of the human blood clots were exposed to ultrasound in the presence of the Actilyse tissue plasminogen activator at a concentration of 10 μg/ml flowing around the sample. Next, the effect of SonoVue microbubbles at a concentration of 5x105/ml on the dissolution of the thrombus was investigated. Thrombus size changes were observed under a 4x magnification microscope and were recorded as a function of time. The best result was achieved for the Actilyse tissue plasminogen activator at the 1 MHz and 1.6 W/cm2 ISATA, the thrombus was sonolysed within 5.5 minutes. The noticeable effect of the SonoVue microbubbles on the thrombolysis process appeared at 3.3 MHz, the thrombus was sonolysed in 12 min at ISATA = 1.6 W/cm2.

Słowa kluczowe:
ultrasound, blood, thrombus, thrombolysis, parallel plate flow chamber

Afiliacje autorów:
Secomski W. - IPPT PAN
Klimonda Z. - IPPT PAN
Majka K. - Military Medical Institute (PL)
Olszewski R. - IPPT PAN
Nowicki A. - IPPT PAN
20p.

Abstrakty konferencyjne
1.  Parol M.A., Majka K., Trawiński Z., Gambin B., Krupienicz A., Obiala J., Nowicki A., Olszewski R., Ultrasonic imaging of radial artery reactive response in patients with hypertension with and without left ventricular hypertrophy, EuroEcho 2019, EuroEcho 2019 Congress of the European Association of Cardiovascular Imaging (EACVI). , 2019-12-04/12-07, Vienna (AT), DOI: 10.1093/ehjci/jez319.1176, Vol.21, No.Suplement 1, pp.i1239-i1239, 2020
2.  Secomski W., Klimonda Z., Majka K., Olszewski R., Nowicki A., Microscopic examination of the sonothrombolysis process inside the transparent to ultrasound parallel plate flow chamber, IUS 2018, IEEE International Ultrasonics Symposium, 2018-10-22/10-25, KOBE (JP), pp.754-754, 201820p.

Kategoria A Plus

IPPT PAN

logo ippt            ul. Pawińskiego 5B, 02-106 Warszawa
  +48 22 826 12 81 (centrala)
  +48 22 826 98 15
 

Znajdź nas

mapka
© Instytut Podstawowych Problemów Techniki Polskiej Akademii Nauk 2021