Instytut Podstawowych Problemów Techniki
Polskiej Akademii Nauk

Partnerzy

B. Zeller-Plumhoff


Ostatnie publikacje
1.  Espiritu J., Sefa S., Ćwieka H., Greving I., Flenner S., Willumeit-Römer R., Seitz J.-M., Zeller-Plumhoff B., Detailing the influence of surface-treated biodegradable magnesium-based implants on the lacuno-canalicular network in sheep bone: A pilot study, Bioactive Materials, ISSN: 2452-199X, DOI: 10.2139/ssrn.4279434, pp.1-26, 2022

Streszczenie:
An increasing prevalence of bone-related injuries and aging geriatric populations continue to drive the orthopaedic implant market. A hierarchical analysis of bone remodelling after material implantation is necessary to better understand the relationship between implant and bone. Osteocytes, which are housed and communicate through the lacuno-canalicular network (LCN), are integral to bone health and remodelling processes. Therefore, it is essential to examine the framework of the LCN in response to implant materials or surface treatments.Biodegradable materials offer an alternative solution to permanent implants, which may require revision or removal surgeries. Magnesium alloys have resurfaced as promising materials due to their bone-like properties and safe degradation in vivo. To further tailor their degradation capabilities, surface treatments such as plasma electrolytic oxidation (PEO) have demonstrated to slow degradation.For the first time, the influence of a biodegradable material on the LCN is investigated by means of non-destructive 3D imaging. In this pilot study, we hypothesise noticeable variations in the LCN caused by altered chemical stimuli introduced by the PEO-coating.Utilising synchrotron-based transmission X-ray microscopy, we have characterised morphological LCN differences around uncoated and PEO-coated WE43 screws implanted into sheep bone. Bone specimens were explanted after 4, 8, and 12 weeks and regions near the implant surface were prepared for imaging. Findings from this investigation indicate that the slower degradation of PEO-coated WE43 induces healthier lacunar shapes within the LCN. However, the stimuli perceived by the uncoated material with higher degradation rates induces a greater connected LCN better prepared for bone disturbance.

Słowa kluczowe:
nanotomography, lacuno-canalicular network, Bone, magnesium, biodegradable implants

Afiliacje autorów:
Espiritu J. - inna afiliacja
Sefa S. - inna afiliacja
Ćwieka H. - IPPT PAN
Greving I. - inna afiliacja
Flenner S. - inna afiliacja
Willumeit-Römer R. - inna afiliacja
Seitz J.-M. - inna afiliacja
Zeller-Plumhoff B. - inna afiliacja
200p.
2.  Sommer N., Hirzberger D., Paar L., Berger L., Ćwieka H., Schwarze U., Herber V., Okutan B., Bodey A., Willumeit-Römer R., Zeller-Plumhoff B., Löffler J., Weinberg A., Implant degradation of low-alloyed Mg-Zn-Ca in osteoporic, old and juvenile rats, Acta Biomaterialia, Acta Biomaterialia, ISSN: 1742-7061, DOI: 10.1016/j.actbio.2022.05.041, Vol.147, pp.427-438, 2022

Streszczenie:
Implant removal is unnecessary for biodegradable magnesium (Mg)-based implants and, therefore, the related risk for implant-induced fractures is limited. Aging, on the other hand, is associated with low bone-turnover and decreased bone mass and density, and thus increased fracture risk. Osteoporosis is accompanied by Mg deficiency, therefore, we hypothesized that Mg-based implants may support bone formation by Mg2+ ion release in an ovariectomy-induced osteoporotic rat model. Hence, we investigated osseointegration and implant degradation of a low-alloyed, degrading Mg–Zn–Ca implant (ZX00) in ovariectomy-induced osteoporotic (Osteo), old healthy (OH), and juvenile healthy (JH) groups of female Sprague Dawley rats via in vivo micro-computed tomography (µCT). For the Osteo rats, we demonstrate diminished trabecular bone already after 8 weeks upon ovariectomy and significantly enhanced implant volume loss, with correspondingly pronounced gas formation, compared to the OH and JH groups. Sclerotic rim development was observed in about half of the osteoporotic rats, suggesting a prevention from foreign-body and osteonecrosis development. Synchrotron radiation-based µCT confirmed lower bone volume fractions in the Osteo group compared to the OH and JH groups. Qualitative histological analysis additionally visualized the enhanced implant degradation in the Osteo group. To date, ZX00 provides an interesting implant material for young and older healthy patients, but it may not be of advantage in pharmacologically untreated osteoporotic conditions.

Słowa kluczowe:
Magnesium-based implants, Osteoporosis, Degradation, Histology, Micro-computed tomography, Synchrotron radiation

Afiliacje autorów:
Sommer N. - inna afiliacja
Hirzberger D. - inna afiliacja
Paar L. - inna afiliacja
Berger L. - inna afiliacja
Ćwieka H. - IPPT PAN
Schwarze U. - inna afiliacja
Herber V. - inna afiliacja
Okutan B. - inna afiliacja
Bodey A. - inna afiliacja
Willumeit-Römer R. - inna afiliacja
Zeller-Plumhoff B. - inna afiliacja
Löffler J. - inna afiliacja
Weinberg A. - inna afiliacja
140p.
3.  Marek R., Ćwieka H., Donouhue N., Holweg P., Moosmann J., Beckmann F., Brcic I., Schwarze U. Y., Iskhakova K., Chaabane M., Sefa S., Zeller-Plumhoff B., Weinberg A., Willumeit-Römer R., Sommer N., Degradation behavior and osseointegration of Mg-Zn-Ca screws in different bone regions of growing sheep, regenerative biomaterials, ISSN: 2056-3418, DOI: 10.1093/rb/rbac077, Vol.rbac077, pp.26-60, 2022

Streszczenie:
Magnesium (Mg)-based implants are highly attractive for the orthopedic field and may replace titanium (Ti) as support for fracture healing. To determine the implant-bone-interaction in different bony regions, we implanted Mg-based alloy ZX00 (Mg < 0.5 Zn < 0.5 Ca, in wt%) and Ti-screws into the distal epiphysis and distal metaphysis of sheep tibiae. The implant degradation and osseointegration were assessed in vivo and ex vivo after 4, 6 and 12 weeks, using a combination of clinical computed tomography (cCT), medium-resolution micro CT (µCT) and high-resolution synchrotron radiation µCT (SRµCT). Implant volume loss, gas formation, and bone growth were evaluated for both implantation sites and each bone region independently. Additionally, histological analysis of bone growth was performed on embedded hard-tissue samples. We demonstrate that in all cases, the degradation rate of ZX00-implants ranges between 0.23-0.75 mm/year. The highest degradation rates were found in the epiphysis. Bone-to-implant-contact varied between the time points and bone types for both materials. Mostly, bone-volume-to-total-volume was higher around Ti-implants. However, we found an increased cortical thickness around the ZX00-screws when compared to the Ti-screws. Our results showed the suitability of ZX00-screws for implantation into the distal meta- and epiphysis

Słowa kluczowe:
Biodegradable implants,Magnesium-based alloys,Computed tomography,Mg-Zn-Ca,Sheep,Histology

Afiliacje autorów:
Marek R. - inna afiliacja
Ćwieka H. - IPPT PAN
Donouhue N. - inna afiliacja
Holweg P. - inna afiliacja
Moosmann J. - inna afiliacja
Beckmann F. - inna afiliacja
Brcic I. - inna afiliacja
Schwarze U. Y. - inna afiliacja
Iskhakova K. - inna afiliacja
Chaabane M. - inna afiliacja
Sefa S. - inna afiliacja
Zeller-Plumhoff B. - inna afiliacja
Weinberg A. - inna afiliacja
Willumeit-Römer R. - inna afiliacja
Sommer N. - inna afiliacja
40p.
4.  Zeller-Plumhoff B., Laipple D., Słomińska H., Iskhakova K., Longo E., Hermann A., Flenner S., Greving I., Storm M., Willumeit-Romer R., Evaluating the morphology of the degradation layer of pure magnesium via 3D imaging at resolutions below 40 nm, Bioactive Materials, ISSN: 2452-199X, DOI: 10.1016/j.bioactmat.2021.04.009, Vol.6, No.12, pp.4368-4376, 2021

Streszczenie:
Magnesium is attractive for the application as a temporary bone implant due to its inherent biodegradability, non-toxicity and suitable mechanical properties. The degradation process of magnesium in physiological environments is complex and is thought to be a diffusion-limited transport problem. We use a multi-scale imaging approach using micro computed tomography and transmission X-ray microscopy (TXM) at resolutions below 40 nm. Thus, we are able to evaluate the nanoporosity of the degradation layer and infer its impact on the degradation process of pure magnesium in two physiological solutions. Magnesium samples were degraded in simulated body fluid (SBF) or Dulbecco's modified Eagle's medium (DMEM) with 10% fetal bovine serum (FBS) for one to four weeks. TXM reveals the three-dimensional interconnected pore network within the degradation layer for both solutions. The pore network morphology and degradation layer composition are similar for all samples. By contrast, the degradation layer thickness in samples degraded in SBF was significantly higher and more inhomogeneous than in DMEM+10%FBS. Distinct features could be observed within the degradation layer of samples degraded in SBF, suggesting the formation of microgalvanic cells, which are not present in samples degraded in DMEM+10%FBS. The results suggest that the nanoporosity of the degradation layer and the resulting ion diffusion processes therein have a limited influence on the overall degradation process. This indicates that the influence of organic components on the dampening of the degradation rate by the suppression of microgalvanic degradation is much greater in the present study.

Słowa kluczowe:
magnesium degradation, porosity, transmission X-ray microscopy, 3D imaging

Afiliacje autorów:
Zeller-Plumhoff B. - inna afiliacja
Laipple D. - inna afiliacja
Słomińska H. - IPPT PAN
Iskhakova K. - inna afiliacja
Longo E. - inna afiliacja
Hermann A. - inna afiliacja
Flenner S. - inna afiliacja
Greving I. - inna afiliacja
Storm M. - inna afiliacja
Willumeit-Romer R. - inna afiliacja
200p.
5.  Zeller-Plumhoff B., Gile M., Priebe M., Słomińska H., Boll B., Wiese B., Würger T., Willumeit-Römer R., Horst Meißner R., Exploring key ionic interactions for magnesium degradation in simulated body fluid – a data-driven approach, Corrosion Science, ISSN: 0010-938X, DOI: 10.1016/j.corsci.2021.109272, Vol.182, pp.1-109272-13, 2021

Streszczenie:
We have studied the degradation of pure magnesium wire in simulated body fluid and its subsets under physiological conditions to enable the prediction of the degradation rate based on the medium's ionic composition. To this end, micro-computed tomography and scanning electron microscopy with energy-dispersive X-ray spectroscopy were used, followed by a tree regression analysis. A non-linear relationship was found between degradation rate and the precipitation of calcium salts. The mean absolute error for predicting the degradation rate was 1.35 mm/yr. This comparatively high value indicates that ionic interactions were exceedingly complex or that an unknown parameter determining the degradation may exist.

Słowa kluczowe:
magnesium degradation, simulated body fluid, MicroCT, tree regression

Afiliacje autorów:
Zeller-Plumhoff B. - inna afiliacja
Gile M. - inna afiliacja
Priebe M. - inna afiliacja
Słomińska H. - IPPT PAN
Boll B. - inna afiliacja
Wiese B. - inna afiliacja
Würger T. - inna afiliacja
Willumeit-Römer R. - inna afiliacja
Horst Meißner R. - inna afiliacja
140p.
6.  Meyer S., Wolf A., Sanders D., Iskhakova K., Ćwieka H., Bruns S., Flenner S., Greving I., Hagemann J., Willumeit-Römer R., Wiese B., Zeller-Plumhoff B., Degradation analysis of thin Mg-xAg wires using X-ray near-field holotomography, Metals, ISSN: 2075-4701, DOI: 10.3390/met11091422, Vol.11, No.9, pp.1422-1-12, 2021

Streszczenie:
Magnesium–silver alloys are of high interest for the use as temporary bone implants due to their antibacterial properties in addition to biocompatibility and biodegradability. Thin wires in particular can be used for scaffolding, but the determination of their degradation rate and homogeneity using traditional methods is difficult. Therefore, we have employed 3D imaging using X-ray near-field holotomography with sub-micrometer resolution to study the degradation of thin (250 μm diameter) Mg-2Ag and Mg-6Ag wires. The wires were studied in two states, recrystallized and solution annealed to assess the influence of Ag content and precipitates on the degradation. Imaging was employed after degradation in Dulbecco’s modified Eagle’s medium and 10% fetal bovine serum after 1 to 7 days. At 3 days of immersion the degradation rates of both alloys in both states were similar, but at 7 days higher silver content and solution annealing lead to decreased degradation rates. The opposite was observed for the pitting factor. Overall, the standard deviation of the determined parameters was high, owing to the relatively small field of view during imaging and high degradation inhomogeneity of the samples. Nevertheless, Mg-6Ag in the solution annealed state emerges as a potential material for thin wire manufacturing for implants.

Słowa kluczowe:
X-ray computed tomography, magnesium-silver alloy, wire, degradation, near-field holotomography

Afiliacje autorów:
Meyer S. - inna afiliacja
Wolf A. - inna afiliacja
Sanders D. - inna afiliacja
Iskhakova K. - inna afiliacja
Ćwieka H. - IPPT PAN
Bruns S. - inna afiliacja
Flenner S. - inna afiliacja
Greving I. - inna afiliacja
Hagemann J. - inna afiliacja
Willumeit-Römer R. - inna afiliacja
Wiese B. - inna afiliacja
Zeller-Plumhoff B. - inna afiliacja
70p.
7.  Zeller-Plumhoff B., Robisch A.L., Pelliccia D., Longo E., Słomińska H., Hermann A., Krenkel M., Storm M., Estrin Y., Willumeit-Römer R., Salditt T., Orlov D., Nanotomographic evaluation of precipitate structure evolution in a Mg–Zn–Zr alloy during plastic deformation, Scientific Reports, ISSN: 2045-2322, DOI: 10.1038/s41598-020-72964-x, Vol.10, pp.16101-1-9, 2020

Streszczenie:
Magnesium and its alloys attract increasingly wide attention in various fields, ranging from transport to medical solutions, due to their outstanding structural and degradation properties. These properties can be tailored through alloying and thermo-mechanical processing, which is often complex and multi-step, thus requiring in-depth analysis. In this work, we demonstrate the capability of synchrotron-based nanotomographic X-ray imaging methods, namely holotomography and transmission X-ray microscopy, for the quantitative 3D analysis of the evolution of intermetallic precipitate (particle) morphology and distribution in magnesium alloy Mg–5.78Zn-0.44Zr subjected to a complex multi-step processing. A rich history of variation of the intermetallic particle structure in the processed alloy provided a testbed for challenging the analytical capabilities of the imaging modalities studied. The main features of the evolving precipitate structure revealed earlier by traditional light and electron microscopy methods were confirmed by the 3D techniques of synchrotron-based X-ray imaging. We further demonstrated that synchrotron-based X-ray imaging enabled uncovering finer details of the variation of particle morphology and number density at various stages of processing—above and beyond the information provided by visible light and electron microscopy.

Afiliacje autorów:
Zeller-Plumhoff B. - inna afiliacja
Robisch A.L. - inna afiliacja
Pelliccia D. - inna afiliacja
Longo E. - inna afiliacja
Słomińska H. - inna afiliacja
Hermann A. - inna afiliacja
Krenkel M. - inna afiliacja
Storm M. - inna afiliacja
Estrin Y. - inna afiliacja
Willumeit-Römer R. - inna afiliacja
Salditt T. - inna afiliacja
Orlov D. - inna afiliacja
140p.

Kategoria A Plus

IPPT PAN

logo ippt            ul. Pawińskiego 5B, 02-106 Warszawa
  +48 22 826 12 81 (centrala)
  +48 22 826 98 15
 

Znajdź nas

mapka
© Instytut Podstawowych Problemów Techniki Polskiej Akademii Nauk 2024