Instytut Podstawowych Problemów Techniki
Polskiej Akademii Nauk

Partnerzy

T. Płociński

Warsaw University of Technology (PL)


Ostatnie publikacje
1.  Maj M., Nowak M., Musiał S., Płociński T., Experimental analysis of material, lattice and plastic rotation during deformation of aluminium multicrystal, MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, ISSN: 0921-5093, DOI: 10.1016/j.msea.2020.139725, Vol.790, pp.139725-1-5, 2020

Streszczenie:
This paper focuses on the experimental determination of the distribution of material, lattice and plastic rotation during deformation of crystalline aggregate. The proposed methodology uses standard electron backscattering diffraction technique combined with 3D digital image correlation data. The presented approach is used for analysis of rotations during deformation of aluminium multicrystal.

Słowa kluczowe:
image analysis, electron backscattering diffraction, plastic deformation, misorientation, plastic rotation

Afiliacje autorów:
Maj M. - IPPT PAN
Nowak M. - IPPT PAN
Musiał S. - IPPT PAN
Płociński T. - Warsaw University of Technology (PL)
140p.
2.  Małolepszy A., Błoński S., Chrzanowska-Giżyńska J., Wojasiński M., Płociński T., Stobiński L., Szymański Z., Fluorescent carbon and graphene oxide nanoparticles synthesized by the laser ablation in liquid, APPLIED PHYSICS A-MATERIALS SCIENCE AND PROCESSING, ISSN: 0947-8396, DOI: 10.1007/s00339-018-1711-5, Vol.124, pp.282-1-7, 2018

Streszczenie:
The results of synthesis of the fluorescent carbon dots (CDots) from graphite target and reduced graphene oxide (rGO) nanoparticles performed by the nanosecond laser ablation in polyethylene glycol 200 (PEG200) are shown. Two-step laser irradiation (first graphite target, next achieved suspension) revealed a very effective production of CDots. However, the ablation in PEG appeared to be effective with 1064 nm laser pulse in contrast to the ablation with 355 nm laser pulse. In the case of rGO nanoparticles similar laser irradiation procedure was less efficient. In both cases, received nanoparticles exhibited strong, broadband photoluminescence with a maximum dependent on the excitation wavelength. The size distribution for obtained CDots was evaluated using the DLS technique and HRTEM images. The results from both methods show quite good agreement in nanoparticle size estimation although the DLS method slightly overestimates nanoparticle's diameter

Afiliacje autorów:
Małolepszy A. - Warsaw University of Technology (PL)
Błoński S. - IPPT PAN
Chrzanowska-Giżyńska J. - IPPT PAN
Wojasiński M. - Warsaw University of Technology (PL)
Płociński T. - Warsaw University of Technology (PL)
Stobiński L. - Warsaw University of Technology (PL)
Szymański Z. - IPPT PAN
30p.

Kategoria A Plus

IPPT PAN

logo ippt            ul. Pawińskiego 5B, 02-106 Warszawa
  +48 22 826 12 81 (centrala)
  +48 22 826 98 15
 

Znajdź nas

mapka
© Instytut Podstawowych Problemów Techniki Polskiej Akademii Nauk 2021